MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12880-023-01054-x

Медицинская библиотека · BMC medical imaging · 2023

Direct comparison of diagnostic and clinical values between Tc-99 m DPD and Tc-99 m PYP scintigraphy in patients with cardiac amyloidosis.

Park Yong-Jin, Lee Joohee, Kim Darae, Choi Jin-Oh, Kim Seok Jin, Kim Kihyun, Choi Joon Young

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Technetium-99 m 3,3-diphosphono-1,2-propanodicarboxylic acid (DPD) and technetium-99 m sodium pyrophosphate (PYP) are the two most commonly used radiotracers for cardiac amyloidosis (CA), but no studies have directly compared them. Therefore, in this study, we directly compared the diagnostic and clinical utility of DPD and PYP scintigraphy in patients with CA.

METHODS

Ten patients with CA were enrolled. Eight clinical variables and 12 scintigraphic parameters were used. Clinical variables were age, sex, estimated glomerular filtration rate (eGFR), N-terminal pro brain natriuretic peptide (NT-proBNP), and the results of electromyography (EMG), a sensory test, electrocardiogram, and echocardiography (EchoCG). Four heart retention ratios (heart/whole-body profile, heart/pelvis, heart/skull, and heart/contralateral lung) were calculated from the DPD and PYP scans and two visual scoring systems (Perugini and Dorbala systems) were used. Comparative analyses were performed between radiotracers and between visual scoring systems using clinical variables and scintigraphic parameters.

RESULTS

Twenty DPD parameters and nine PYP parameters had significant associations with age, eGFR, NT-proBNP, EchoCG, and EMG. DPD parameters had more frequent significant associations with clinical variables than PYP parameters. Compared to visual scores in the DPD scan, the proportion of patients with higher visual scores in the PYP scan was relatively greater than those with lower visual scores, and there were more patients with a visual score of 2 or higher in PYP scans than DPD scans.

CONCLUSIONS

DPD scintigraphy may reflect the disease severity of CA better than PYP scintigraphy, whereas PYP scintigraphy may be a more sensitive imaging modality for identifying CA involvement.

Для цитирования: Park Yong-Jin, Lee Joohee, Kim Darae, Choi Jin-Oh, Kim Seok Jin, Kim Kihyun, Choi Joon Young. Direct comparison of diagnostic and clinical values between Tc-99 m DPD and Tc-99 m PYP scintigraphy in patients with cardiac amyloidosis.. BMC medical imaging. 2023. DOI: 10.1186/s12880-023-01054-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.