MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ejrad.2013.05.043

Медицинская библиотека · European journal of radiology · 2013

Contrast-enhanced ultrasound in the differentiation between phlegmon and abscess in Crohn's disease and other abdominal conditions.

Ripollés Tomás, Martínez-Pérez María J, Paredes José M, Vizuete José, García-Martínez Esteban, Jiménez-Restrepo David H

СтатьяПеревод пока не подготовлен

Аннотация

AIM: To evaluate the diagnostic accuracy of the contrast-enhanced ultrasound (CEUS) to differentiate between intra-abdominal phlegmon and abscess.

METHODS

We retrospectively reviewed all contrast-enhanced ultrasound performed between June 2006 and May 2012 to identify patients with the terms "inflammatory mass", "phlegmon" or "abscess" on the sonographic report. The initial CEUS report was used for the diagnosis of phlegmon or abscess.

RESULTS

71 inflammatory masses in 50 patients were identified in CEUS examination. 57 masses, 21 phlegmons and 36 abscesses, were confirmed by other imaging techniques, percutaneous drainage or surgery. CEUS specificity for the diagnosis of abscess was 100%. Kappa coefficient between CEUS and other techniques in the diagnosis of phlegmon or abscess was excellent (kappa=0.972). Only in one patient surgery detected a small abscess (<2 cm) within a phlegmon that not was detected by CEUS. Statistically significant differences were found between the size of the abscesses before and after contrast agent injection. The interobserver agreement in the diagnosis of phlegmon or abscess was excellent (kappa=0.953).

CONCLUSIONS

CEUS is an accurate method for differentiating between intra-abdominal phlegmon and abscess in gastrointestinal conditions, especially in CD. Its use may help to better define the size of the collections and avoid other techniques that use ionizing radiation. CEUS should be used to confirm an inflammatory mass identified at US.

Для цитирования: Ripollés Tomás, Martínez-Pérez María J, Paredes José M, Vizuete José, García-Martínez Esteban, Jiménez-Restrepo David H. Contrast-enhanced ultrasound in the differentiation between phlegmon and abscess in Crohn's disease and other abdominal conditions.. European journal of radiology. 2013. DOI: 10.1016/j.ejrad.2013.05.043.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.