MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1148/radiology.197.3.7480755

Медицинская библиотека · Radiology · 1995

Peripherally inserted central catheters in children.

Chait P G, Ingram J, Phillips-Gordon C, Farrell H, Kuhn C

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To assess the feasibility and complications of peripherally inserted central catheters (PICCs) in pediatric patients.

MATERIALS AND

METHODS

The authors attempted to place PICCs in 122 patients aged 9 days to 19 years (mean, 6.82 years; median, 5 years). Catheters were placed to allow prolonged administration of antibiotics or chemotherapeutic agents (n = 50), provide total parenteral nutrition (n = 41), and establish prolonged intravenous access for blood draws and fluid administration (n = 31). Silicone catheters measuring 3, 4, and 5 F were inserted in either basilic or cephalic veins and positioned at the junction of the superior vena cava and right atrium under fluoroscopic guidance. Patients were monitored for complications until devices were removed.

RESULTS

Fluoroscopically guided PICC placement was successful in 137 of 148 attempts. Postinsertion complications included mechanical defects of the catheter, PICC-related infection, occlusion of the PICC, and venous stasis. Complications occurred at a rate comparable to those seen with blind insertion.

CONCLUSION

Fluoroscopically guided PICC placement is feasible and safe in pediatric patients.

Для цитирования: Chait P G, Ingram J, Phillips-Gordon C, Farrell H, Kuhn C. Peripherally inserted central catheters in children.. Radiology. 1995. DOI: 10.1148/radiology.197.3.7480755.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.