MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/iae.0000000000003950

Медицинская библиотека · Retina (Philadelphia, Pa.) · 2024

LONG-TERM OUTCOMES OF SUTURELESS INTRASCLERAL INTRAOCULAR LENS FIXATION IN CHILDREN AND ADULTS: Single-Surgeon Case Series With and Without Haptic Flanging With Up to 11 Years of Follow-Up.

Moore Spencer M, Bullock Brenna L, Walsh Mark K

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Report and compare long-term outcomes and complications of sutureless scleral tunnel (SST) and flanged haptic (FH) scleral-fixated intraocular lens, with spontaneous intraocular lens (IOL) dislocation as primary outcome measure.

METHODS

Retrospective single-surgeon case series of 95 SST and 458 FH eyes from 2011 to 2022 (553 total eyes). Demographics, surgical indications, ocular history, visual acuity, and complication rates were collected.

RESULTS

Reoperation-requiring spontaneous IOL dislocation rate was significantly different ( P = 0.0167) between FH (3.7%) and SST (10.5%). Mean follow-up was 3.31 ± 0.30 versus 1.58 ± 0.07 years for SST and FH, respectively. There was no significant difference between preoperative (20/305 vs. 20/300) or final postoperative (20/77 vs. 20/62) visual acuity. Other complications included any cystoid macular edema (20.0% vs. 25.3%), elevated intraocular pressure (16.8% vs. 9.6%), IOL tilt requiring reoperation (5.3 vs. 0%), haptic exposure (2.1% vs. 3.3%), and reverse pupillary block (4.2% vs. 1.1%).

CONCLUSION

Haptic flanging resulted in fewer eyes meeting the primary end point of IOL dislocation. We reported the longest-to-date follow-up of both nonflanged SST IOL fixation and our FH-modified Yamane technique. Our FH-modified Yamane technique represents a safe, durable, and potentially superior option for scleral-fixated intraocular lens.

Для цитирования: Moore Spencer M, Bullock Brenna L, Walsh Mark K. LONG-TERM OUTCOMES OF SUTURELESS INTRASCLERAL INTRAOCULAR LENS FIXATION IN CHILDREN AND ADULTS: Single-Surgeon Case Series With and Without Haptic Flanging With Up to 11 Years of Follow-Up.. Retina (Philadelphia, Pa.). 2024. DOI: 10.1097/iae.0000000000003950.