MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jbiomech.2024.112281

Медицинская библиотека · Journal of biomechanics · 2024

Repeatability and minimal detectable change including clothing effects for smartphone-based 3D markerless motion capture.

Horsak Brian, Kainz Hans, Dumphart Bernhard

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OpenCap, a smartphone- and web-based markerless system, has shown acceptable accuracy compared to marker-based systems, but lacks information on repeatability. This study fills this gap by evaluating the intersession repeatability of OpenCap and investigating the effects of clothing on gait kinematics. Twenty healthy volunteers participated in a test-retest study, performing walking and sit-to-stand tasks with minimal clothing and regular street wear. Segment lengths and lower-limb kinematics were compared between both sessions and for both clothing conditions using the root-mean-square-deviation (RMSD) for entire waveforms and the standard error of measurement (SEM) and minimal detectable change (MDC) for discrete kinematic parameters. In general, the RMSD test-retest values were 2.8 degrees (SD: 1.0) for walking and 3.3 degrees (SD: 1.2) for sit-to-stand. The highest intersession variability was observed in the trunk, pelvis, and hip kinematics of the sagittal plane. SEM and MDC values were on average 2.2 and 6.0 degrees, respectively, for walking, and 2.4 and 6.5 degrees for sit-to-stand. Clothing had minimal effects on kinematics by adding on average less than one degree to the RMSD values for most variables. The segment lengths showed moderate to excellent agreement between both sessions and poor to moderate agreement between clothing conditions. The study highlights the reliability of OpenCap for markerless motion capture, emphasizing its potential for large-scale field studies. However, some variables showed high MDC values above 5 degrees and thus warrant further enhancement of the technology. Although clothing had minimal effects, it is still recommended to maintain consistent clothing to minimize overall variability.

Для цитирования: Horsak Brian, Kainz Hans, Dumphart Bernhard. Repeatability and minimal detectable change including clothing effects for smartphone-based 3D markerless motion capture.. Journal of biomechanics. 2024. DOI: 10.1016/j.jbiomech.2024.112281.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.