Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology · 2018

Comparison of butterfly volumetric modulated arc therapy to full arc with or without deep inspiration breath hold for the treatment of mediastinal lymphoma.

Сравнительное исследованиеСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Starke Alison, Bowden Jonathan, Lynn Rebecca, Hall Keith, Hudson Kate, Rato Ana, Aldridge Emma, Robb Dean, Steele Paula, Brady Jessica, Mikhaeel Nabegh George

Аннотация

PURPOSE: Radiotherapy is an effective treatment for mediastinal lymphoma but induces late effects including cardiac toxicity and secondary breast and lung cancer. Therefore reducing the dose to these organs is vital. We compared full arc volumetric modulated arc therapy (F-VMAT) against limited angle 'Butterfly' VMAT (B-VMAT) on free breathing (FB) and deep inspiration breath-hold (DIBH) computed tomography scans. The aim was to assess the benefits of B-VMAT over F-VMAT and to establish if the addition of DIBH results is a cumulative benefit.

MATERIALS AND METHODS: F-VMAT and B-VMAT plans were calculated for 20 consecutive patients (15 females) with mediastinal lymphoma on both FB and DIBH scans. The planning target volume V95% was kept comparable between all plans while reducing organ doses as much as possible.

RESULTS: B-VMAT significantly reduced low lung doses (V5-10), while F-VMAT was better for higher lung doses (V20-30). DIBH further improved lung doses for both types of plans. DIBH B-VMAT produced the lowest mean lung dose. With FB, heart doses were slightly higher for B-VMAT but the maximum difference was small (0.8% for V20) and only statistically significant for V10-20. The mean heart dose increased by only 0.1 Gy. The addition of DIBH however significantly reduced heart doses. While DIBH F-VMAT had the lowest heart doses, the difference was small compared with DIBH B-VMAT. B-VMAT significantly reduced breast V4 while DIBH reduced the V10.

CONCLUSION: B-VMAT and DIBH are both effective in reducing organ doses and the dosimetric benefit is additive for some parameters and complementary for others.