Efficacy of the spiral flow generating extended tube during paediatric CCTA.

Masuda T, Funama Y, Nakaura T, Sato T, Tahara M, Yamashita Y, Yoshiura T, Masuda S, Gotanda R, Arao K, Imaizumi H, Arao S, Hiratsuka J, Awai K

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

To compare the computed tomography (CT) number for paediatric cardiac computed tomography angiography (CCTA) and visualisation score of the three-dimensional (3D) images using the conventional T-shaped extended tube (T-tube) and spiral flow-generating extended tube (spiral-tube) connected between the contrast injector and cannula.

METHODS

In total, 108 patients suspected to have congenital heart disease (CHD) were considered for inclusion. We utilised the T-tube for intravenous contrast and spiral-tube in 54 patients each. Observers individually inspected randomized volume rendering images of the internal thoracic artery, each acquired from the with or without spiral-tube groups, using a four-point scale. We compared the mean CT number of the ascending aorta (AAO) and pulmonary artery (PA), contrast noise ratio (CNR), CT number for the AAO and PA enhancement ratio, and the visualisation scores between the groups.

RESULTS

There were no significant differences in patient characteristics between the with or without spiral-tube groups (p > 0.05). The mean CT number ±standard deviation for the AAO and PA, and the CNR without or with spiral-tube groups were 441.2 ± 89.2 and 489.8 ± 86.1 HU for the AAO, 436.3 ± 100.6 and 475.3 ± 85.2 HU for the PA, and 9.5 ± 2.2 and 10.8 ± 2.4 for the CNR, respectively (p < 0.05). In the spiral-tube group, the CT number, CNR, and visualisations score of the 3D images were significantly higher for the AAO and PA than those in the T-tube group (p < 0.05).

CONCLUSION

The spiral-tube proved to be beneficial in improving the CT number for the AAO and PA, CNR, and visualisation score compared with the conventional T-tube during paediatric CCTA.

IMPLICATIONS FOR PRACTICE: The spiral-tube may allow the visualisation of smaller blood vessels than those visualised by the conventional T-tube for paediatric patients in CCTA.

Для цитирования: Masuda T, Funama Y, Nakaura T, Sato T, Tahara M, Yamashita Y, Yoshiura T, Masuda S, Gotanda R, Arao K, Imaizumi H, Arao S, Hiratsuka J, Awai K. Efficacy of the spiral flow generating extended tube during paediatric CCTA.. Radiography (London, England : 1995). 2021. DOI: 10.1016/j.radi.2021.10.007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.