MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10840-007-9177-y

Медицинская библиотека · Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2007

Minimally invasive pulmonary vein isolation and partial autonomic denervation for surgical treatment of atrial fibrillation.

Edgerton James R, Jackman Warren M, Mack Michael J

Клиническое исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

It was our goal to determine the efficacy of a minimally invasive surgical approach to the treatment of atrial fibrillation that combines pulmonary vein antral isolation with targeted partial autonomic denervation.

METHODS

Eighty-three patients underwent video-assisted bilateral pulmonary vein antral electrical isolation with confirmation of block and partial autonomic denervation. Sixty-two (41 paroxysmal, 21 persistent/long-standing persistent) patients had a follow-up of 6 months or greater. Fifty-seven of these patients had a long-term rhythm monitor at 6 months (39 paroxysmal, 18 persistent/long-standing persistent).

RESULTS

Success was defined as no episodes of atrial fibrillation greater than 15 s duration on long-term monitoring. Treatment was successful in 32 of 39 (82.1%) patients with paroxysmal atrial fibrillation and 10 of 18 (55.6%) with persistent/long-standing persistent atrial fibrillation.

CONCLUSION

Early data suggest that pulmonary vein electrical isolation combined with targeted partial autonomic denervation is a safe and efficacious approach for the treatment of paroxysmal atrial fibrillation. Techniques are being developed for the minimally invasive surgical treatment of persistent and long-standing persistent atrial fibrillation from an epicardial approach.

Для цитирования: Edgerton James R, Jackman Warren M, Mack Michael J. Minimally invasive pulmonary vein isolation and partial autonomic denervation for surgical treatment of atrial fibrillation.. Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing. 2007. DOI: 10.1007/s10840-007-9177-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.