Comparison of T2 values of the displaced unilateral disc and retrodiscal tissue of temporomandibular joints and their implications.

Kakimoto Naoya, Wongratwanich Pongsapak, Shimamoto Hiroaki, Kitisubkanchana Jira, Tsujimoto Tomomi, Shimabukuro Kiichi, Verdonschot Rinus G, Hasegawa Yoko, Murakami Shumei

СтатьяПеревод пока не подготовлен

Аннотация

Unilateral anterior disc displacement (uADD) has been shown to affect the contralateral joints qualitatively. This study aims to assess the quantitative T2 values of the articular disc and retrodiscal tissue of patients with uADD at 1.5 Tesla (T). The study included 65 uADD patients and 17 volunteers. The regions of interest on T2 maps were evaluated. The affected joints demonstrated significantly higher articular disc T2 values (31.5 ± 3.8 ms) than those of the unaffected joints (28.9 ± 4.5 ms) (P < 0.001). For retrodiscal tissue, T2 values of the unaffected (37.8 ± 5.8 ms) and affected joints (41.6 ± 7.1 ms) were significantly longer than those of normal volunteers (34.4 ± 3.2 ms) (P < 0.001). Furthermore, uADD without reduction (WOR) joints (43.3 ± 6.8 ms) showed statistically higher T2 values than the unaffected joints of both uADD with reduction (WR) (33.9 ± 3.8 ms) and uADDWOR (38.9 ± 5.8 ms), and the affected joints of uADDWR (35.8 ± 4.4 ms). The mean T2 value of the unaffected joints of uADDWOR was significantly longer than that of healthy volunteers (P < 0.001). These results provided quantitative evidence for the influence of the affected joints on the contralateral joints.

Для цитирования: Kakimoto Naoya, Wongratwanich Pongsapak, Shimamoto Hiroaki, Kitisubkanchana Jira, Tsujimoto Tomomi, Shimabukuro Kiichi, Verdonschot Rinus G, Hasegawa Yoko, Murakami Shumei. Comparison of T2 values of the displaced unilateral disc and retrodiscal tissue of temporomandibular joints and their implications.. Scientific reports. 2024. DOI: 10.1038/s41598-024-52092-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.