MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.hrthm.2016.06.024

Медицинская библиотека · Heart rhythm · 2016

Minimally invasive epicardial implantable cardioverter-defibrillator placement for infants and children: An effective alternative to the transvenous approach.

Schneider Andrew E, Burkhart Harold M, Ackerman Michael J, Dearani Joseph A, Wackel Philip, Cannon Bryan C

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Young patients have high rates of implantable cardioverter-defibrillator (ICD) lead fractures and are at risk for venous occlusion or tricuspid regurgitation with transvenous lead placement. Epicardial ICDs have the potential to circumvent complications associated with transvenous ICDs, but the literature on young patients remains limited.

OBJECTIVE

The purpose of this study was to evaluate the results of a minimally invasive epicardial ICD lead placement approach in young patients.

METHODS

A retrospective, institutional review board-approved electronic medical record review of all patients undergoing epicardial ICD placement at our institution from January 2011 to December 2015 was performed.

RESULTS

A total of 46 patients (20 female [43%]; mean age 10.3 years, range 0.7-18.2 years; mean weight 41 ± 21 kg) were identified; 24 (52%) were ≤10 years old. A minithoracotomy was used in 28 patients (61%). All had acceptable defibrillation, right ventricular sensing, and stimulation thresholds. Median follow-up was 2.0 ± 1.3 years (range 0.02-4.5 years). Eight surgical complications occurred in 7 patients (15%), and 8 device-related complications occurred in 6 patients (13%). Fifty-eight appropriate shocks were delivered in 7 patients (15%). Four patients received inappropriate shocks in relation to lead fractures/microfractures. One patient in this cohort who had long QT syndrome type 8 died of a hypoglycemic seizure.

CONCLUSION

Minimally invasive epicardial ICD placement provides an effective, alternative method for implanting an ICD system, particularly in very young patients (<6 years of age) or patients who are concerned about cosmetic appearance. This technique is an acceptable alternative to traditional transvenous ICD placement.

Для цитирования: Schneider Andrew E, Burkhart Harold M, Ackerman Michael J, Dearani Joseph A, Wackel Philip, Cannon Bryan C. Minimally invasive epicardial implantable cardioverter-defibrillator placement for infants and children: An effective alternative to the transvenous approach.. Heart rhythm. 2016. DOI: 10.1016/j.hrthm.2016.06.024.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.