MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.mayocp.2021.06.029

Медицинская библиотека · Mayo Clinic proceedings · 2021

The Impact of Charlson Comorbidity Index on De Novo Cardiac Implantable Electronic Device Procedural Outcomes in the United States.

Mohamed Mohamed O, Van Spall Harriette G C, Morillo Carlos, Wilton Steve B, Kontopantelis Evangelos, Rashid Muhammad, Wu Pensee, Patwala Ashish, Mamas Mamas A

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To investigate the utility of Charlson comorbidity index (CCI) as a measure of comorbidity burden to predict procedural outcomes after de novo cardiac implantable electronic device (CIED) implantation.

METHODS

All de novo CIED implantations in the United States National Inpatient Sample between 2015 and 2018 were retrospectively analyzed, stratified by CCI score (0=no comorbidity burden, 1=mild, 2=moderate, ≥3=severe). Multivariable logistic regression models were performed to examine the association between unit CCI score (scale) and in-hospital outcomes (major adverse cerebrovascular and cardiovascular events [MACCE]: composite of all-cause mortality, acute ischemic stroke, thoracic and cardiac complications, and device-related complications; and MACCE individual components).

RESULTS

Of 474,475 CIED procedures, the distribution of CCI score was as follows: CCI=0 (17.7%), CCI=1 (21.8%), CCI=2 (18.7%), and CCI=3+ (41.8%). Charlson comorbidity index score was associated with increased odds ratios of MACCE (1.10; 95% CI, 1.09 to 1.11), all-cause mortality (1.23; 95% CI, 1.21 to 1.25), and acute stroke (1.45; 95% CI, 1.44 to 1.46). This finding was consistent across all CIED groups except the cardiac resynchronization therapy groups in which CCI was not associated with increased risk of mortality. A higher CCI score was not associated with increased odds of procedural (thoracic and cardiac) and device-related complications.

CONCLUSION

In a nationwide cohort of CIED procedures, higher comorbidity burden as measured by CCI score was associated with an increased risk of in-hospital mortality and acute ischemic stroke, but not procedure-related (thoracic and cardiac) or device-related complications. Objective assessment of comorbidity burden is important to risk-stratify patients undergoing CIED implantation for better prognostication of their in-hospital survival.

Для цитирования: Mohamed Mohamed O, Van Spall Harriette G C, Morillo Carlos, Wilton Steve B, Kontopantelis Evangelos, Rashid Muhammad, Wu Pensee, Patwala Ashish, Mamas Mamas A. The Impact of Charlson Comorbidity Index on De Novo Cardiac Implantable Electronic Device Procedural Outcomes in the United States.. Mayo Clinic proceedings. 2021. DOI: 10.1016/j.mayocp.2021.06.029.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.