MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/jaha.120.019051

Медицинская библиотека · Journal of the American Heart Association · 2021

Impact of Morbid Obesity and Obesity Phenotype on Outcomes After Transcatheter Aortic Valve Replacement.

McInerney Angela, Tirado-Conte Gabriela, Rodes-Cabau Josep, Campelo-Parada Francisco, Tafur Soto Jose D, Barbanti Marco, Muñoz-Garcia Erika, Arif Mobeena, Lopez Diego, Toggweiler Stefan, Veiga Gabriela, Pylko Anna, Sevilla Teresa, Compagnone Miriam, Regueiro Ander, Serra Viçent, Carnero Manuel, Oteo Juan F, Rivero Fernando, Barbosa Ribeiro Henrique, Guimaraes Leonardo, Matta Anthony, Giraldo Echavarria Natalia, Valvo Roberto, Moccetti Federico, Muñoz-Garcia Antonio J, Lopez-Pais Javier, Garcia Del Blanco Bruno, Campanha Borges Diego Carter, Dumont Eric, Gonzalo Nieves, Criscione Enrico, Dabrowski Maciej, Alfonso Fernando, de la Torre Hernández Jose M, Cheema Asim N, Amat-Santos Ignacio J, Saia Francesco, Escaned Javier, Nombela-Franco Luis

СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАVideo-Audio MediaПеревод пока не подготовлен

Аннотация

Background There is a paucity of outcome data on patients who are morbidly obese (MO) undergoing transcatheter aortic valve replacement. We aimed to determine their periprocedural and midterm outcomes and investigate the impact of obesity phenotype. Methods and Results Consecutive patients who are MO (body mass index, ≥40 kg/m2, or ≥35 kg/m2 with obesity-related comorbidities; n=910) with severe aortic stenosis who underwent transcatheter aortic valve replacement in 18 tertiary hospitals were compared with a nonobese cohort (body mass index, 18.5-29.9 kg/m2, n=2264). Propensity-score matching resulted in 770 pairs. Pre-transcatheter aortic valve replacement computed tomography scans were centrally analyzed to assess adipose tissue distribution; epicardial, abdominal visceral and subcutaneous fat. Major vascular complications were more common (6.6% versus 4.3%; P=0.043) and device success was less frequent (84.4% versus 88.1%; P=0.038) in the MO group. Freedom from all-cause and cardiovascular mortality were similar at 2 years (79.4 versus 80.6%, P=0.731; and 88.7 versus 87.4%, P=0.699; MO and nonobese, respectively). Multivariable analysis identified baseline glomerular filtration rate and nontransfemoral access as independent predictors of 2-year mortality in the MO group. An adverse MO phenotype with an abdominal visceral adipose tissue:subcutaneous adipose tissue ratio ≥1 (VAT:SAT) was associated with increased 2-year all-cause (hazard ratio [HR], 3.06; 95% CI, 1.20-7.77; P=0.019) and cardiovascular (hazard ratio, 4.11; 95% CI, 1.06-15.90; P=0.041) mortality, and readmissions (HR, 1.81; 95% CI, 1.07-3.07; P=0.027). After multivariable analysis, a (VAT:SAT) ratio ≥1 remained a strong predictor of 2-year mortality (hazard ratio, 2.78; P=0.035). Conclusions Transcatheter aortic valve replacement in patients who are MO has similar short- and midterm outcomes to nonobese patients, despite higher major vascular complications and lower device success. An abdominal VAT:SAT ratio ≥1 identifies an obesity phenotype at higher risk of adverse clinical outcomes.

Для цитирования: McInerney Angela, Tirado-Conte Gabriela, Rodes-Cabau Josep, Campelo-Parada Francisco, Tafur Soto Jose D, Barbanti Marco, Muñoz-Garcia Erika, Arif Mobeena, Lopez Diego, Toggweiler Stefan, Veiga Gabriela, Pylko Anna, Sevilla Teresa, Compagnone Miriam, Regueiro Ander, Serra Viçent, Carnero Manuel, Oteo Juan F, Rivero Fernando, Barbosa Ribeiro Henrique, Guimaraes Leonardo, Matta Anthony, Giraldo Echavarria Natalia, Valvo Roberto, Moccetti Federico, Muñoz-Garcia Antonio J, Lopez-Pais Javier, Garcia Del Blanco Bruno, Campanha Borges Diego Carter, Dumont Eric, Gonzalo Nieves, Criscione Enrico, Dabrowski Maciej, Alfonso Fernando, de la Torre Hernández Jose M, Cheema Asim N, Amat-Santos Ignacio J, Saia Francesco, Escaned Javier, Nombela-Franco Luis. Impact of Morbid Obesity and Obesity Phenotype on Outcomes After Transcatheter Aortic Valve Replacement.. Journal of the American Heart Association. 2021. DOI: 10.1161/jaha.120.019051.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.