DOI 10.1016/j.jvir.2024.12.595
Percutaneous Biodegradable Stent Placement for Treatment of Benign Biliary Strictures: A Systematic Review.
Аннотация
PURPOSE: To assess whether safety profile and treatment success of percutaneous biodegradable biliary stent placement are competitive with traditional options for treatment of benign biliary strictures.
MATERIALS AND
METHODS
PubMed and Embase were systematically reviewed for articles reporting percutaneous biodegradable stent placement for treating benign biliary strictures. Databases were searched for articles until December 2023, with the earliest included article dating April 2016. Treatment outcome was assessed by evaluating outcomes described in the included articles, including technical success of stent placement, migration rates, restenosis rates, time to restenosis, and biochemical liver panel measures. Stent safety was assessed by examining stent placement-related adverse events and occurrence of cholangitis after placement.
RESULTS
Seven of 39 studies in the primary search met the inclusion criteria and were further analyzed. All included studies were cases series, totaling 323 stent placements. High rates of technical success were observed (98%-100%). Bile duct patency rates following biodegradable stent placement ranged from 94% (3-month follow-up) to 72% (60-month follow-up). The most frequently reported adverse event was hemobilia, followed by fever and pain.
CONCLUSIONS
Available literature reports high technical success in initial placement of biodegradable stents for benign biliary strictures, and the technique seems safe. Further investigation with comparison arms is warranted to establish this technique as the preferred management for benign biliary strictures.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.