MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ultrasmedbio.2010.02.002

Медицинская библиотека · Ultrasound in medicine & biology · 2010

Feasibility of in vivo transesophageal cardiac ablation using a phased ultrasound array.

Werner Jacob, Park Eun-Joo, Lee Hotaik, Francischelli David, Smith Nadine Barrie

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Over 2.2 million Americans suffer from atrial fibrillation making it one of the most common arrhythmias. Cardiac ablation has shown a high rate of success in treating paroxysmal atrial fibrillation. Prevailing modalities for this treatment are catheter based radio-frequency ablation or surgery. However, there is measurable morbidity and significant costs and time associated with these invasive procedures. Due to these issues, developing a method that is less invasive to treat atrial fibrillation is needed. In the development of such a device, a transesophageal ultrasound applicator for cardiac ablation was designed, constructed and evaluated. A goal of this research was to create lesions in myocardial tissue using a phased array. Based on multiple factors from array simulations, transesophageal imaging devices and throat anatomy, a phased ultrasound transducer that can be inserted into the esophagus was designed and tested. In this research, a two-dimensional sparse phased array with the aperture size of 20.7 mm x 10.2 mm with flat tapered elements as a transesophageal ultrasound applicator was fabricated and evaluated with in vivo experiments. Five pigs were anesthetized; the array was passed through the esophagus and positioned over the heart. The array was operated for 8-15 min at 1.6 MHz with the acoustic intensity of 150-300 W/cm(2) resulting in both single and multiple lesions on atrial and ventricular myocardium. The average size of lesions was 5.1 +/- 2.1 mm in diameter and 7.8 +/- 2.5 mm in length. Based on the experimental results, the array delivered sufficient power to the focal point to produce ablation while not grossly damaging nearby tissue outside the target area. These results demonstrate a potential application of the ultrasound applicator to transesophageal cardiac surgery in atrial fibrillation treatment.

Для цитирования: Werner Jacob, Park Eun-Joo, Lee Hotaik, Francischelli David, Smith Nadine Barrie. Feasibility of in vivo transesophageal cardiac ablation using a phased ultrasound array.. Ultrasound in medicine & biology. 2010. DOI: 10.1016/j.ultrasmedbio.2010.02.002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.