MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ultrasmedbio.2020.12.010

Медицинская библиотека · Ultrasound in medicine & biology · 2021

Quantitative In Vivo Monitoring of Hypoxia and Vascularization of Patient-Derived Murine Xenografts of Mantle Cell Lymphoma Using Photoacoustic and Ultrasound Imaging.

Keša Peter, Pokorná Eva, Grajciarová Martina, Tonar Zbyněk, Vočková Petra, Trochet Philippe, Kopeček Milan, Jakša Radek, Šefc Luděk, Klener Pavel

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Tumor oxygenation and vascularization are important parameters that determine the aggressiveness of the tumor and its resistance to cancer therapies. We introduce dual-modality ultrasound and photoacoustic imaging (US-PAI) for the direct, non-invasive real-time in vivo evaluation of oxygenation and vascularization of patient-derived xenografts (PDXs) of B-cell mantle cell lymphomas. The different optical properties of oxyhemoglobin and deoxyhemoglobin make it possible to determine oxygen saturation (sO2) in tissues using PAI. High-frequency color Doppler imaging enables the visualization of blood flow with high resolution. Tumor oxygenation and vascularization were studied in vivo during the growth of three different subcutaneously implanted patient-derived xenograft (PDX) lymphomas (VFN-M1, VFN-M2 and VFN-M5 R1). Similar values of sO2 (sO2 Vital), determined from US-PAI volumetric analysis, were obtained in small and large VFN-M1 tumors ranging from 37.9 ± 2.2 to 40.5 ± 6.0 sO2 Vital (%) and 37.5 ± 4.0 to 35.7 ± 4.6 sO2 Vital (%) for small and large VFN-M2 PDXs. In contrast, the higher sO2 Vital values ranging from 57.1 ± 4.8 to 40.8 ± 5.7 sO2 Vital (%) (small to large) of VFN-M5 R1 tumors corresponds with the higher aggressiveness of that PDX model. The different tumor percentage vascularization (assessed as micro-vessel areas) of VFN-M1, VFN-M2 and VFN-M5 R1 obtained by color Doppler (2.8 ± 0.1%, 3.8 ± 0.8% and 10.3 ± 2.7%) in large-stage tumors clearly corresponds with their diverse growth and aggressiveness. The data obtained by color Doppler were validated by histology. In conclusion, US-PAI rapidly and accurately provided relevant and reproducible information on tissue oxygenation in PDX tumors in real time without the need for a contrast agent.

Для цитирования: Keša Peter, Pokorná Eva, Grajciarová Martina, Tonar Zbyněk, Vočková Petra, Trochet Philippe, Kopeček Milan, Jakša Radek, Šefc Luděk, Klener Pavel. Quantitative In Vivo Monitoring of Hypoxia and Vascularization of Patient-Derived Murine Xenografts of Mantle Cell Lymphoma Using Photoacoustic and Ultrasound Imaging.. Ultrasound in medicine & biology. 2021. DOI: 10.1016/j.ultrasmedbio.2020.12.010.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.