A canine head phantom for quality assurance in multiport microbeam radiation therapy: animal phantom fabrication and dosimetry protocol.

Bustillo John Paul O, de Rover Vincent, Engels Elette E M, Cayley James, Cameron Matthew, Long Sam, Carolan Martin, Frerker Bernd, Lerch Michael L F, Schültke Elisabeth

СтатьяПеревод пока не подготовлен

Аннотация

Objective. This study aims to develop canine radiotherapy phantoms and a dosimetry protocol for synchrotron microbeam radiation therapy (MRT).Approach. Two canine head phantoms were designed based on computed tomography (CT) image sets obtained from veterinary patients. Polylactic acid polymer and calcium sulfate hemihydrate plaster were used to radiologically simulate soft tissue and bone. Fused deposition modeling 3D printing was used to fabricate the external geometry of the head phantoms. CT images of the phantoms were acquired to measure its CT number profile and to create treatment plans. Using a 4 Tesla superconducting multipole wiggler field and in vacuo filters, synchrotron beam was delivered as broad-beam and as microbeam arrays at the imaging and medical beamline of the Australian Synchrotron. The Monte Carlo simulated dose using a hybrid EclipseTMtreatment planning system (TPS) was compared to the experimental measurements.Main results. The head phantoms offer a realistic three-dimensional canine head geometry and CT numbers mimicking soft tissue and bone. Various types of detectors and biological samples can be accomodated, using a series of customizable rectangular inserts. The measured accumulated doses for microbeam irradiation were within +/-2% of the TPS doses, while all the other measured doses were within +/-10% agreement with the TPS doses. The TPS, phantom positioning, and detector uncertainties contributed to the measurement discrepancies.Significance and conclusions. The 3D printed canine phantoms were shown to be useful dosimetry tool for synchrotron MRT end-to-end quality assurance. The development of canine phantoms and dosimetry methodology are critical for the treatment plan optimization required in future veterinary studies. Both the phantoms and the dosimetry protocol are valuable tools in future veterinary MRT trials.

Для цитирования: Bustillo John Paul O, de Rover Vincent, Engels Elette E M, Cayley James, Cameron Matthew, Long Sam, Carolan Martin, Frerker Bernd, Lerch Michael L F, Schültke Elisabeth. A canine head phantom for quality assurance in multiport microbeam radiation therapy: animal phantom fabrication and dosimetry protocol.. Biomedical physics & engineering express. 2025. DOI: 10.1088/2057-1976/adff8b.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.