MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · Pediatrics · 1996

A single-sample, subcutaneous gonadotropin-releasing hormone test for central precocious puberty.

Eckert K L, Wilson D M, Bachrach L K, Anhalt H, Habiby R L, Olney R C, Hintz R L, Neely E K

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

We compared a rapid, subcutaneous (SQ), single-sample gonadotropin-releasing hormone (GnRH) stimulation test with the standard multiple-sample, intravenous (IV) GnRH stimulation test used in the evaluation of central precocious puberty (CPP).

METHODS

We evaluated 22 patients presenting with evidence of precocious puberty. GnRH (100 microg) was administered subcutaneously in the clinic setting with single serum luteinizing hormone (LH) measured 40 minutes after injection. A standard IV GnRH stimulation test was performed within 2 weeks, with serum LH obtained at 0, 20, 40, and 60 minutes. LH was assayed by immunochemiluminometric assay.

RESULTS

The mean peak LH levels after IV and SQ testing were identical. A significant correlation (r = .88) was found between the LH determined by SQ stimulations and the peak LH determined by IV GnRH testing. CPP was diagnosed (LH, >/- 8 IU/L) by both SQ and IV testing in 7 of 22 patients and was excluded by both tests in 14 of 22 patients. A diagnostic discrepancy between peak IV and SQ results was seen in 1 patient.

CONCLUSIONS

We conclude that mean GnRH-stimulated LH levels from rapid SQ and standard IV testing are indistinguishable and that individual LH levels by each method are strongly correlated. A rapid SQ GnRH test is a valid tool for laboratory confirmation of CPP.

Для цитирования: Eckert K L, Wilson D M, Bachrach L K, Anhalt H, Habiby R L, Olney R C, Hintz R L, Neely E K. A single-sample, subcutaneous gonadotropin-releasing hormone test for central precocious puberty.. Pediatrics. 1996.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.