MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41598-024-64508-4

Медицинская библиотека · Scientific reports · 2024

Unobtrusive measurement of gait parameters using seismographs: An observational study.

Single Michael, Bruhin Lena C, Naef Aileen C, Krack Paul, Nef Tobias, Gerber Stephan M

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

Analyzing irregularities in walking patterns helps detect human locomotion abnormalities that can signal health changes. Traditional observation-based assessments have limitations due to subjective biases and capture only a single time point. Ambient and wearable sensor technologies allow continuous and objective locomotion monitoring but face challenges due to the need for specialized expertise and user compliance. This work proposes a seismograph-based algorithm for quantifying human gait, incorporating a step extraction algorithm derived from mathematical morphologies, with the goal of achieving the accuracy of clinical reference systems. To evaluate our method, we compared the gait parameters of 50 healthy participants, as recorded by seismographs, and those obtained from reference systems (a pressure-sensitive walkway and a camera system). Participants performed four walking tests, including traversing a walkway and completing the timed up-and-go (TUG) test. In our findings, we observed linear relationships with strong positive correlations (R2 > 0.9) and tight 95% confidence intervals for all gait parameters (step time, cycle time, ambulation time, and cadence). We demonstrated that clinical gait parameters and TUG mobility test timings can be accurately derived from seismographic signals, with our method exhibiting no significant differences from established clinical reference systems.

Для цитирования: Single Michael, Bruhin Lena C, Naef Aileen C, Krack Paul, Nef Tobias, Gerber Stephan M. Unobtrusive measurement of gait parameters using seismographs: An observational study.. Scientific reports. 2024. DOI: 10.1038/s41598-024-64508-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.