MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.clinbiomech.2024.106267

Медицинская библиотека · Clinical biomechanics (Bristol, Avon) · 2024

Biomechanical improvements in gait following medial pivot knee implant surgery.

Dabirrahmani D, Farshidfar S, Cadman J, Shahidian H, Kark L, Sullivan J, Appleyard R

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Total knee replacements are used to improve function and reduce pain in patients with advanced osteoarthritis. The medially stabilising implant is designed to mimic a healthy knee. This study aims to provide a comprehensive analysis of the kinematics and kinetics of a medially stabilising knee implant, comparing it to a healthy control group, as well as to its pre-operative state and the contralateral limb.

METHODS

Sixteen total knee replacement patients and ten healthy participants were recruited. Patients underwent testing 4-6 weeks before surgery and repeated the same tests 12 months after surgery. Healthy participants completed the same tests at a single time point. All participants completed three walking trials: kinematics was captured with eight cameras; kinetics with in-ground force plates. Subject-specific musculoskeletal models were developed in OpenSim. Inverse kinematics and inverse dynamics were used to determine gait parameters. Joint angles and joint moments were evaluated using Statistical Parametric Mapping. Patient-reported outcome measures were also collected at both time points.

FINDINGS: Spatiotemporal results indicate significant differences in velocity and step length between pre-operative patients and control participants. Differences are observed in the adduction angles between the contralateral and ipsilateral limbs pre-operatively. Postoperatively, there was an increase in the 1st peak flexion moment, reduced adduction moment and reduced internal rotation moment. In PROMs, patients all report improvements in pain levels and high satisfaction levels following surgery.

INTERPRETATIONS: Following medial stabilising total knee arthroplasty, patients displayed improved clinical parameters and joint moments reflecting a shift towards more normal, healthy gait.

Для цитирования: Dabirrahmani D, Farshidfar S, Cadman J, Shahidian H, Kark L, Sullivan J, Appleyard R. Biomechanical improvements in gait following medial pivot knee implant surgery.. Clinical biomechanics (Bristol, Avon). 2024. DOI: 10.1016/j.clinbiomech.2024.106267.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.