MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jpba.2015.01.027

Медицинская библиотека · Journal of pharmaceutical and biomedical analysis · 2015

Multiplexed LC-MS/MS method for the simultaneous quantitation of three novel hepatitis C antivirals, daclatasvir, asunaprevir, and beclabuvir in human plasma.

Jiang Hao, Kandoussi Hamza, Zeng Jianing, Wang Jian, Demers Roger, Eley Timothy, He Bing, Burrell Richard, Easter John, Kadiyala Pathanjali, Pursley Janice, Cojocaru Laura, Baker Chanda, Ryan John, Aubry Anne-Françoise, Arnold Mark E

СтатьяПеревод пока не подготовлен

Аннотация

Dual or triple combination regimens of novel hepatitis C direct-acting antivirals (DAA, daclatasvir, asunaprevir, or beclabuvir) provide high sustained virological response rates and reduced frequency of resistance compared to clinical monotherapy. To support pharmacokinetic (PK) assessments in clinical studies, a multiplexed liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the simultaneous quantitation of daclatasvir, asunaprevir, beclabuvir (BMS-791325) and its active metabolite (BMS-794712) in human plasma was developed and validated. Human plasma samples were extracted with methyl-t-butyl ether followed by an LC-MS/MS analysis, which was conducted in a multiple reaction monitoring (MRM) mode. The lower limits of quantitation (LLOQ) were 1 ng/mL for daclatasvir, asunaprevir, and BMS-794712, and 2 ng/mL for beclabuvir. Intra-run precision (≤4.5% CV), inter-run precision (≤2.9% CV), and accuracy (±5.3% deviation) based on different concentration levels (low, geometric mean, mid and high) of the quality control samples (QCs) provided evidence of the methods accuracy and precision. Selectivity and matrix effect on LC-MS/MS detection, stability in plasma, and potential interference of coadministered drugs (ribavirin and interferon) were all evaluated and the results were acceptable. Method reproducibility was demonstrated by the reanalysis of a portion of study samples. The cross-validation results for QCs demonstrated the equivalency between this method and two single-analyte methods which were previously validated for quantitation of daclatasvir in human plasma. This approach of using a multiplexed LC-MS/MS method for the simultaneous quantitation of three DAAs is time- and cost-effective, and can maintain good data quality in sample analysis.

Для цитирования: Jiang Hao, Kandoussi Hamza, Zeng Jianing, Wang Jian, Demers Roger, Eley Timothy, He Bing, Burrell Richard, Easter John, Kadiyala Pathanjali, Pursley Janice, Cojocaru Laura, Baker Chanda, Ryan John, Aubry Anne-Françoise, Arnold Mark E. Multiplexed LC-MS/MS method for the simultaneous quantitation of three novel hepatitis C antivirals, daclatasvir, asunaprevir, and beclabuvir in human plasma.. Journal of pharmaceutical and biomedical analysis. 2015. DOI: 10.1016/j.jpba.2015.01.027.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.