MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00134-009-1652-8

Медицинская библиотека · Intensive care medicine · 2009

Diagnostic considerations regarding pediatric delirium: a review and a proposal for an algorithm for pediatric intensive care units.

Schieveld Jan N M, van der Valk Judith A, Smeets Inge, Berghmans Eline, Wassenberg Renske, Leroy Piet L M N, Vos Gijs D, van Os Jim

СтатьяОбзорПеревод пока не подготовлен

Аннотация

CONTEXT: If delirium is not diagnosed, it is unlikely that any effort will be made to reverse it. Given evidence for under-diagnosis, tools that aid recognition are required.

OBJECTIVE

Relating three presentations of pediatric delirium (PD) to standard criteria and developing a diagnostic algorithm.

RESULTS

Delirium-inducing factors, disturbance of consciousness and inattention are common in PICU patients: a pre-delirious state is present in most. An algorithm is introduced, containing (1) evaluation of the sedation-agitation level, (2) psychometric assessment of behavior and (3) opinion of the caregivers.

DISCUSSION: It may be argued that the behavioral focus of the algorithm would benefit from the inclusion of neurocognitive measures.

LIMITATIONS: No sufficiently validated diagnostic instrument covering the entire algorithm is available yet.

CONCLUSION

This is the first proposal for a PD diagnostic algorithm. Given the high prevalence of predelirious states at the PICU, daily evaluation is mandatory. Future algorithmic refinement is urgently required.

Для цитирования: Schieveld Jan N M, van der Valk Judith A, Smeets Inge, Berghmans Eline, Wassenberg Renske, Leroy Piet L M N, Vos Gijs D, van Os Jim. Diagnostic considerations regarding pediatric delirium: a review and a proposal for an algorithm for pediatric intensive care units.. Intensive care medicine. 2009. DOI: 10.1007/s00134-009-1652-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.