Медицинская библиотека · Cardiovascular engineering and technology · 2022

Patient-Specific Modelling and Parameter Optimisation to Simulate Dilated Cardiomyopathy in Children.

Bozkurt Selim, Paracha Waleed, Bakaya Kaushiki, Schievano Silvia

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Lumped parameter modelling has been widely used to simulate cardiac function and physiological scenarios in cardiovascular research. Whereas several patient-specific lumped parameter models have been reported for adults, there is a limited number of studies aiming to simulate cardiac function in children. The aim of this study is to simulate patient-specific cardiovascular dynamics in children diagnosed with dilated cardiomyopathy, using a lumped parameter model.

METHODS

Patient data including age, gender, heart rate, left and right ventricular end-systolic and end-diastolic volumes, cardiac output, systolic and diastolic aortic pressures were collected from 3 patients at Great Ormond Street Hospital for Children, London, UK. Ventricular geometrical data were additionally retrieved from cardiovascular magnetic resonance images. 23 parameters in the lumped parameter model were optimised to simulate systolic and diastolic pressures, end-systolic and end-diastolic volumes, cardiac output and left and right ventricular diameters in the patients using a direct search optimisation method.

RESULTS

Difference between the haemodynamic parameters in the optimised cardiovascular system models and clinical data was less than 10%.

CONCLUSION

The simulation results show the potential of patient-specific lumped parameter modelling to simulate clinical cases. Modelling patient specific cardiac function and blood flow in the paediatric patients would allow us to evaluate a variety of physiological scenarios and treatment options.

Для цитирования: Bozkurt Selim, Paracha Waleed, Bakaya Kaushiki, Schievano Silvia. Patient-Specific Modelling and Parameter Optimisation to Simulate Dilated Cardiomyopathy in Children.. Cardiovascular engineering and technology. 2022. DOI: 10.1007/s13239-022-00611-9.