MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1055/s-2007-1006018

Медицинская библиотека · Ultraschall in der Medizin (Stuttgart, Germany : 1980) · 1985

[Thyroid gland and parathyroid gland changes in ultrasound (real time B image)].

Brockmann W P, Crone-Münzebrock W, Steinhagen E, Spengler D

Аннотация на английскомСтатьяПеревод пока не подготовлен

Аннотация

Using a high-resolution real-time B-imager, examinations of the thyroid and parathyroid glands of 112 patients revealed small focal lesions (more than 3 mm diameter: thyroid gland, parathyroid gland) as well as diffuse alterations (thyroid gland). The following focal lesions were found: Adenomas of the parathyroid gland (n = 9), haemangiomas of thyroid gland (n = 3), adenomas of thyroid gland (n = 2), metastases into the thyroid gland (n = 7), primary cancer of the thyroid gland or its recurrence (n = 3) and metastases of different cancers in soft tissue of the neck regions (n = 8). A struma nodosa was diagnosed in 15 patients. With regard to diffuse alterations of the thyroid gland, atrophies (n = 6), aplasieas of 1 lobe (n = 2), thyreoiditides (n = 3), and struma diffuse (n = 5). In 49 of 52 cases morphological alterations of the thyroid gland could be excluded, while for the other 3 patients, who had been operated on in the region of the neck, no final evaluation was possible. On comparing these findings with the results of computed tomography and scintigraphy, ultrasound as a screening method showed the highest sensitivity while its specificity could be enlarged by considering the results of scintigraphy. Decision by ultrasound only as to whether a focal lesion was benign or malignant was only possible under certain circumstances. However, a histological diagnosis could not be made by ultrasound.

Для цитирования: Brockmann W P, Crone-Münzebrock W, Steinhagen E, Spengler D. [Thyroid gland and parathyroid gland changes in ultrasound (real time B image)].. Ultraschall in der Medizin (Stuttgart, Germany : 1980). 1985. DOI: 10.1055/s-2007-1006018.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.