MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.otohns.2004.07.002

Медицинская библиотека · Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery · 2004

Can history and physical examination reliably diagnose pediatric obstructive sleep apnea/hypopnea syndrome? A systematic review of the literature.

Brietzke Scott E, Katz Eliot S, Roberson David W

СтатьяПоддержка исследования: вне правительства СШАПоддержка службы здравоохранения СШАСистематический обзорПеревод пока не подготовлен

Аннотация

OBJECTIVE

Using an evidence-based technique, systematically review the literature to evaluate the accuracy of routine clinical history and physical examination in the diagnosis of obstructive sleep apnea/hypopnea syndrome (OSAHS) in the pediatric patient.

STUDY DESIGN AND

SETTING

The biomedical literature was systematically reviewed. Articles comparing the results of clinical evaluation to polysomnography (PSG) were selected. The level of evidence was assessed using established evidence-based medicine (EBM) guidelines.

RESULTS

Twelve articles were identified using the search criteria. Eleven of 12 articles concluded that clinical evaluation is inaccurate in the diagnosis of OSAHS. The level of evidence was good to very good (Grade B/B+).

CONCLUSION/SIGNIFICANCE: Clinical history and physical examination are not reliable for diagnosing OSAHS compared with overnight PSG. Complicating the interpretation of this work is the lack of a validated PSG threshold of clinically significant disease. There is an urgent need for the development of adequate screening tests with validated clinical outcomes.

EBM RATING: B-3.

Для цитирования: Brietzke Scott E, Katz Eliot S, Roberson David W. Can history and physical examination reliably diagnose pediatric obstructive sleep apnea/hypopnea syndrome? A systematic review of the literature.. Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery. 2004. DOI: 10.1016/j.otohns.2004.07.002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.