BACKGROUND

Amyloid PET/CT is essential for quantifying amyloid-beta (Aβ) deposition in Alzheimer's disease (AD), with the Centiloid (CL) scale standardizing measurements across imaging centers. However, MRI-based CL pipelines face challenges: high cost, contraindications, and patient burden. To address these challenges, we developed a deep learning-based CT parcellation pipeline calibrated to the standard CL scale using CT images from PET/CT scans and evaluated its performance relative to standard pipelines.

METHODS

A total of 306 participants (23 young controls [YCs] and 283 patients) underwent 18 F-florbetaben (FBB) PET/CT and MRI. Based on visual assessment, 207 patients were classified as Aβ-positive and 76 as Aβ-negative. PET images were processed using the CT parcellation pipeline and compared to FreeSurfer (FS) and standard pipelines. Agreement was assessed via regression analyses. Effect size, variance, and ROC analyses were used to compare pipelines and determine the optimal CL threshold relative to visual Aβ assessment.

RESULTS

The CT parcellation showed high concordance with the FS and provided reliable CL quantification (R² = 0.99). Both pipelines demonstrated similar variance in YCs and effect sizes between YCs and ADCI. ROC analyses confirmed comparable accuracy and similar CL thresholds, supporting CT parcellation as a viable MRI-free alternative.

CONCLUSIONS

Our findings indicate that the CT parcellation pipeline achieves a level of accuracy similar to FS in CL quantification, demonstrating its reliability as an MRI-free alternative. In PET/CT, CT and PET are acquired sequentially within the same session on a shared bed and headrest, which helps maintain consistent positioning and adequate spatial alignment, reducing registration errors and supporting more reliable and precise quantification.

Для цитирования: Yoon Yeo Jun, Seo Seungbeom, Lee Sangwon, Lim Hyunkeong, Choo Kyobin, Kim Daesung, Han Hyunkyung, So Minjae, Kang Hosung, Kang Seongjin, Kim Dongwoo, Lee Young-Gun, Shin Dongho, Jeon Tae Joo, Yun Mijin. Centiloid values from deep learning-based CT parcellation: a valid alternative to freesurfer.. Alzheimer's research & therapy. 2025. DOI: 10.1186/s13195-025-01860-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.