Evaluation of paediatric head CT radiation dose in Jordan: A new national diagnostic reference level survey.

СтатьяМногоцентровое исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Hamedat S F, Md Radzi Y, Salman M D, Al-Shipli M A

Аннотация

INTRODUCTION: Paediatric head CT scans are essential for diagnosing various neurological conditions. However, they pose radiation risks due to children's heightened sensitivity to ionizing radiation. The absence of standardized national dose-response lines (DRLs) in Jordan contributes to considerable dose variability across hospitals.

METHODS: This retrospective multicenter study evaluated 1550 pediatric head CT examinations performed between February and November 2024 in eight Jordanian hospitals. Patients were grouped into four age categories: <1, 1-5, 5-10, and 10-15 years. Radiation dose metrics, including CTDIvol and DLP, were collected. DRLs were established based on the 75th percentile of dose distributions. Statistical analysis was performed using SPSS to assess inter-hospital variability. DRLs were established using age-based categories, as patient weight data were not consistently available across hospitals, which is acknowledged as a methodological limitation.

RESULTS: Substantial differences in CTDIvol and DLP values were observed across hospitals and age groups. For infants (<1 year), median DLP values ranged from 409.6 to 550.9 mGy cm. Hospitals B and D recorded the highest radiation levels, while Hospitals F and H consistently reported lower values across all age groups.

CONCLUSION: The findings highlight an urgent need for national dose standardization in pediatric CT imaging in Jordan. Establishing local DRLs based on international benchmarks is critical to ensure safe and consistent practices.

IMPLICATIONS FOR PRACTICE: This study underscores the need to improve radiation safety in paediatric CT imaging across Jordan. Radiology staff should receive ongoing training in paediatric dose optimization, including the use of age- and size-specific protocols, automated exposure control, and iterative or deep learning reconstruction techniques. Furthermore, implementing protocol standardization and national regulatory oversight will help ensure adherence to safe radiation practices.