MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00259-023-06363-5

Медицинская библиотека · European journal of nuclear medicine and molecular imaging · 2023

Quantification of P-glycoprotein function at the human blood-brain barrier using [18F]MC225 and PET.

Mossel Pascalle, Arif Wejdan M, De Souza Giordana Salvi, Varela Lara Garcia, van der Weijden Chris W J, Boersma Hendrikus H, Willemsen Antoon T M, Boellaard Ronald, Elsinga Philip H, Borra Ronald J H, Dierckx Rudi A J O, Lammertsma Adriaan A, Bartels Anna L, Luurtsema Gert

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

P-glycoprotein (P-gp) is one of the most studied efflux transporters at the blood-brain barrier. It plays an important role in brain homeostasis by protecting the brain from a variety of endogenous and exogeneous substances. Changes in P-gp function are associated both with the onset of neuropsychiatric diseases, including Alzheimer's disease and Parkinson's disease, and with drug-resistance, for example in treatment-resistant depression. The most widely used approach to measure P-gp function in vivo is (R)-[11C]verapamil PET. (R)-[11C]verapamil is, however, an avid P-gp substrate, which complicates the use of this tracer to measure an increase in P-gp function as its baseline uptake is already very low. [18F]MC225 was developed to measure both increases and decreases in P-gp function.

AIM: The aim of this study was (1) to identify the pharmacokinetic model that best describes [18F]MC225 kinetics in the human brain and (2) to determine test-retest variability.

METHODS

Five (2 male, 3 female) of fourteen healthy subjects (8 male, 6 female, age 67 ± 5 years) were scanned twice (injected dose 201 ± 47 MBq) with a minimum interval of 2 weeks between scans. Each scanning session consisted of a 60-min dynamic [18F]MC225 scan with continuous arterial sampling. Whole brain grey matter data were fitted to a single tissue compartment model, and to reversible and irreversible two tissue-compartment models to obtain various outcome parameters (in particular the volume of distribution (VT), Ki, and the rate constants K1 and k2). In addition, a reversible two-tissue compartment model with fixed k3/k4 was included. The preferred model was selected based on the weighted Akaike Information Criterion (AIC) score. Test-retest variability (TRTV) was determined to assess reproducibility.

RESULTS

Sixty minutes post-injection, the parent fraction was 63.8 ± 4.0%. The reversible two tissue compartment model corrected for plasma metabolites with an estimated blood volume (VB) showed the highest AIC weight score of 34.3 ± 17.6%. The TRVT of the VT for [18F]MC225 PET scans was 28.3 ± 20.4% for the whole brain grey matter region using this preferred model.

CONCLUSION

[18F]MC225 VT, derived using a reversible two-tissue compartment model, is the preferred parameter to describe P-gp function in the human BBB. This outcome parameter has an average test-retest variability of 28%.

TRIAL REGISTRATION: EudraCT 2020-001564-28 . Registered 25 May 2020.

Для цитирования: Mossel Pascalle, Arif Wejdan M, De Souza Giordana Salvi, Varela Lara Garcia, van der Weijden Chris W J, Boersma Hendrikus H, Willemsen Antoon T M, Boellaard Ronald, Elsinga Philip H, Borra Ronald J H, Dierckx Rudi A J O, Lammertsma Adriaan A, Bartels Anna L, Luurtsema Gert. Quantification of P-glycoprotein function at the human blood-brain barrier using [18F]MC225 and PET.. European journal of nuclear medicine and molecular imaging. 2023. DOI: 10.1007/s00259-023-06363-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.