MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4103/ijo.ijo_1113_24

Медицинская библиотека · Indian journal of ophthalmology · 2024

Effective prism diopter for strabismus measurement: Conversion from anterior Prentice position to posterior parallel position and from glass prism to acrylic prism.

Zou Leilei, Liu Hong, Wang Shu, Tian Tian, Fang Cheng, Luo Gang, Liu Rui

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: In clinical ophthalmology, prisms, commonly made of glass, are labeled based on the prism diopter (PD) value measured in the anterior Prentice position. However, they are often used in the posterior parallel position for practicality, causing a discrepancy between labeled and effective PD. This study proposes a conversion tool to address this issue.

METHODS

Geometric optical analysis was employed to calculate the effective PD of glass prisms in the posterior parallel position. A lookup table was created to convert the labeled PD of the anterior Prentice position to the effective PD when the prism is used in the posterior parallel position. Clinical data from 162 patients with horizontal strabismus were collected to validate the method. Glass prism measurements, converted to effective PD, were compared with acrylic prism results.

RESULTS

The variations were significant in glass prism PD with rotation in the anterior Prentice position but stability in the posterior parallel position. Clinical deviations were larger with glass prisms, especially exceeding 30 PD, compared with acrylic prisms. Converted PD from glass prisms correlated well with acrylic prisms (R 2 = 0.94, P = 0.002). The half-width of the 95% limit of agreement was ±12.32 PD.

CONCLUSION

The proposed conversion table is valid, facilitating consistency between clinical and literature-based prism use in different positions and materials.

Для цитирования: Zou Leilei, Liu Hong, Wang Shu, Tian Tian, Fang Cheng, Luo Gang, Liu Rui. Effective prism diopter for strabismus measurement: Conversion from anterior Prentice position to posterior parallel position and from glass prism to acrylic prism.. Indian journal of ophthalmology. 2024. DOI: 10.4103/ijo.ijo_1113_24.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.