MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.arth.2011.09.013

Медицинская библиотека · The Journal of arthroplasty · 2011

Diabetes mellitus, hemoglobin A1C, and the incidence of total joint arthroplasty infection.

Iorio Richard, Williams Kelly M, Marcantonio Andrew J, Specht Lawrence M, Tilzey John F, Healy William L

СтатьяПеревод пока не подготовлен

Аннотация

Patients with diabetes have a higher incidence of infection after total joint arthroplasty (TJA) than patients without diabetes. Hemoglobin A1c (HbA1c) levels are a marker for blood glucose control in diabetic patients. A total of 3468 patients underwent 4241 primary or revision total hip arthroplasty or total knee arthroplasty at one institution. Hemoglobin A1c levels were examined to evaluate if there was a correlation between the control of HbA1c and infection after TJA. There were a total of 46 infections (28 deep and 18 superficial [9 cellulitis and 9 operative abscesses]). Twelve (3.43%) occurred in diabetic patients (n = 350; 8.3%) and 34 (0.87%) in nondiabetic patients (n = 3891; 91.7%) (P < .001). There were 9 deep (2.6%) infections in diabetic patients and 19 (0.49%) in nondiabetic patients. In noninfected, diabetic patients, HbA1c level ranged from 4.7% to 15.1% (mean, 6.92%). In infected diabetic patients, HbA1c level ranged from 5.1% to 11.7% (mean, 7.2%) (P < .445). The average HbA1c level in patients with diabetes was 6.93%. Diabetic patients have a significantly higher risk for infection after TJA. Hemoglobin A1c levels are not reliable for predicting the risk of infection after TJA.

Для цитирования: Iorio Richard, Williams Kelly M, Marcantonio Andrew J, Specht Lawrence M, Tilzey John F, Healy William L. Diabetes mellitus, hemoglobin A1C, and the incidence of total joint arthroplasty infection.. The Journal of arthroplasty. 2011. DOI: 10.1016/j.arth.2011.09.013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.