MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00330-021-08295-w

Медицинская библиотека · European radiology · 2021

Clinical utility of 3D magnetic resonance elastography in patients with biliary obstruction.

Ma Yujia, Wang Guoxin, Gao Feng, Ma Bing, Song Qike, Zhong Shiling, Liu Yuanyuan, Hong Yang

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

Three-dimensional magnetic resonance elastography (3D-MRE) allows for multiparametric modeling of both elastic and viscous tissue characteristics. Our aim was to compare 3D-MRE with conventional liver shear stiffness assessment in gauging obstructive jaundice (OJ), predicting the adequacy of biliary decompression after drainage, and discriminating OJ from liver fibrosis.

METHODS

Patients with no histories of liver disease (n = 201) were studied in retrospect, grouped by bilirubin levels as no jaundice (NJ ≤ 2 mg/dL; n = 75), mild OJ (>2 mg/dL and ≤ 4 mg/dL; n = 56), and severe OJ (> 4 mg/dL; n = 70). For comparison, another 75 patients with chronic hepatitis B and C infections and histologically proven liver fibrosis were similarly analyzed. Each patient underwent spin-echo echo-planar-imaging MRE at 60 Hz with 3D wave postprocessing. Logistic regression and ordinary regression models were used to compare the 3D-MRE model with liver shear stiffness.

RESULTS

Liver shear stiffness, loss modulus, and damping ratio were incorporated into a 3D-MRE model, which significantly outperformed shear stiffness in predicting OJ severity (accuracy: 0.801 vs 0.672; p < 0.001). Both the 3D-MRE model and liver shear stiffness performed equally well in predicting the outcome of biliary drainage procedure (C-statistics: 0.852 vs 0.847; p = 0.48). The 3D-MRE model also demonstrated significantly better C-statistics than that of liver shear stiffness in discriminating mild OJ from F1-F2 liver fibrosis (0.765 vs 0.641; p = 0.005) and severe OJ from F3-F4 liver fibrosis (0.750 vs 0.635; p = 0.031).

CONCLUSIONS

3D-MRE is an innovative imaging method for gauging OJ severity, predicting the outcome of biliary drainage procedure, and discriminating OJ from liver fibrosis.

KEY POINTS: • 3D-MR elastography achieved promising results for predicting the severity of obstructive jaundice. • Advanced parameters of 3D-MR elastography demonstrated significantly better performance than that of shear stiffness of 2D-MR elastography in discriminating obstructive jaundice from liver fibrosis caused by chronic hepatitis B/C. • Both 3D-MR elastography and 2D-MR elastography were equivalent in predicting the outcome of biliary drainage procedure.

Для цитирования: Ma Yujia, Wang Guoxin, Gao Feng, Ma Bing, Song Qike, Zhong Shiling, Liu Yuanyuan, Hong Yang. Clinical utility of 3D magnetic resonance elastography in patients with biliary obstruction.. European radiology. 2021. DOI: 10.1007/s00330-021-08295-w.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.