DOI 10.1016/j.jpeds.2023.113487
Single-Center Analysis of Essential Laboratory Testing in Patients with Newly Diagnosed Celiac Disease.
Аннотация
OBJECTIVE
To analyze laboratory testing results from pediatric patients newly diagnosed with celiac disease to determine the usefulness of each test derived from recommended guidelines.
METHODS
Serological testing at the time of diagnosis from patients enrolled in our celiac disease registry from January 2018 through December 2021 was reviewed. The incidence of abnormal laboratory results, routinely obtained as per the recommendations of Snyder et al and our institution's Celiac Care Index, was assessed. Rates of abnormal laboratory values and estimated costs associated with these screening measures were analyzed.
RESULTS
Our data demonstrated abnormalities in all serological testing obtained at celiac diagnosis. Hemoglobin, alanine aminotransferase, ferritin, iron, and vitamin D screening were found to be abnormal with notable frequency. Only 7% of patients had an abnormal thyroid-stimulating hormone and <0.1% had an abnormal free T4. Nonresponse to hepatitis B vaccination was prominent, with 69% of patients considered nonimmune. Screening protocols as currently outlined in our Celiac Care Index resulted in an estimated cost of approximately $320 000 during our study.
CONCLUSIONS
Review of screening laboratory results at our center reveals that abnormal values for several recommended measures are uncommon. Thyroid screening was infrequently abnormal and the usefulness of screening for hepatitis B at diagnosis is uncertain. Similarly, our data suggest that iron deficiency screening may be condensed effectively into hemoglobin and ferritin testing, eliminating the need for initial iron studies. Decreasing baseline screening measures could safely decrease the burden of testing on patients and overall healthcare expenditures.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.