MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1515/cclm-2022-1045

Медицинская библиотека · Clinical chemistry and laboratory medicine · 2023

Multicenter study to compare the diagnostic performance of CLIA vs. FEIA transglutaminase IgA assays for the diagnosis of celiac disease.

Castelijn Daan A R, Mulder A H Leontine, van der Pol Pieter, Hollander Jolien C, Kuiper Tietie, Bijnens Caroline, Damoiseaux Jan, Bontkes Hetty J

Многоцентровое исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

Celiac disease (CD) is an immune-mediated enteropathy driven by gluten intake. Presence of tTG-IgA antibodies is important for the diagnosis. However, different tTG-IgA assays are used and test performance may vary. Therefore, a retrospective multicenter study was performed to compare the diagnostic performance of three assays.

METHODS

The fluorescence enzyme-linked immunoassay (FEIA) EliA Celikey IgA (Phadia), the chemiluminescence immunoassays (CLIA) h-tTG IgA QUANTA Flash® (Inova Diagnostics) and the anti-tTG ChLIA IgA (Euroimmun) were compared. Diagnostic samples from CD cases (95 adults; 65 children) and controls (479 adults; 253 children) were included. Samples were blinded and reanalyzed on all platforms.

RESULTS

A high quantitative correlation between platforms was found (p<0.0001). Both CLIA were more sensitive (adults 100%; children 100%) compared to the FEIA (adults 88.4%; children 96.6%). Specificity of all assays was high (≥97.6%) with the FEIA having the highest specificity. A cut-off based on receiver operator characteristic analysis (6.5 U/mL) improved the sensitivity of the FEIA (adults 95.8%; children 100%) without affecting specificity. Cut-off values for the CLIA assays did not need further optimization. With the FEIA, 71% of pediatric cases had a tTG-IgA level ≥10× upper limit of normal compared to 91 and 92% with QUANTA Flash and ChLIA, respectively.

CONCLUSIONS

All platforms have high diagnostic accuracy. The CLIA assays are more sensitive compared to the FEIA assay. A lower cut-off for the FEIA improves diagnostic performance, particularly in adult cases that, as demonstrated in this study, present with lower tTG-IgA levels compared to pediatric cases.

Для цитирования: Castelijn Daan A R, Mulder A H Leontine, van der Pol Pieter, Hollander Jolien C, Kuiper Tietie, Bijnens Caroline, Damoiseaux Jan, Bontkes Hetty J. Multicenter study to compare the diagnostic performance of CLIA vs. FEIA transglutaminase IgA assays for the diagnosis of celiac disease.. Clinical chemistry and laboratory medicine. 2023. DOI: 10.1515/cclm-2022-1045.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.