DOI 10.1016/j.jiph.2022.10.028
Validation of RT-qPCR test for SARS-CoV-2 in saliva specimens.
Аннотация
BACKGROUND
Saliva samples may be an easier, faster, safer, and cost-saving alternative to NPS samples, and can be self-collected by the patient. Whether SARS-CoV-2 RT-qPCR in saliva is more accurate than in nasopharyngeal swaps (NPS) is uncertain. We evaluated the accuracy of the RT-qPCR in both types of samples, assuming both approaches were imperfect.
METHODS
We assessed the limit of detection (LoD) of RT-qPCR in each type of sample. We collected paired NPS and saliva samples and tested them using the Berlin Protocol to detect SARS-CoV-2 envelope protein (E). We used a Bayesian latent class analysis (BLCA) to estimate the sensitivity and specificity of each test, while accounting for their conditional dependence.
RESULTS
The LoD were 10 copies/mL in saliva and 100 copies/mL in NPS. Paired samples of saliva and NPS were collected in 412 participants. Out of 68 infected cases, 14 were positive only in saliva. RT-qPCR sensitivity ranged from 82.7 % (95 % CrI: 54.8, 94.8) in NPS to 84.5 % (50.9, 96.5) in saliva. Corresponding specificities were 99.1 % (95 % CrI: 95.3, 99.8) and 98.4 %(95 % CrI: 92.8, 99.7).
CONCLUSIONS
SARS-CoV-2 RT-qPCR test in saliva specimens has a similar or better accuracy than RT-qPCR test in NPS. Saliva specimens may be ideal for surveillance in general population, particularly in children, and in healthcare or other personnel in need of serial testing.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.