MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12936-015-0940-8

Медицинская библиотека · Malaria journal · 2015

Quantification of Plasmodium ex vivo drug susceptibility by flow cytometry.

Wirjanata Grennady, Handayuni Irene, Prayoga Pak, Apriyanti Dwi, Chalfein Ferryanto, Sebayang Boni F, Kho Steven, Noviyanti Rintis, Kenangalem Enny, Campo Brice, Poespoprodjo Jeanne Rini, Price Ric N, Marfurt Jutta

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

The emergence and spread of multidrug-resistant Plasmodium falciparum and Plasmodium vivax highlights the need for objective measures of ex vivo drug susceptibility. Flow cytometry (FC) has potential to provide a robust and rapid quantification of ex vivo parasite growth.

METHODS

Field isolates from Papua, Indonesia, underwent ex vivo drug susceptibility testing against chloroquine, amodiaquine, piperaquine, mefloquine, and artesunate. A single nucleic acid stain (i.e., hydroethidine (HE) for P. falciparum and SYBR Green I (SG) for P. vivax) was used to quantify infected red blood cells by FC-based signal detection. Data derived by FC were compared to standard quantification by light microscopy (LM). A subset of isolates was used to compare single and double staining techniques.

RESULTS

In total, 57 P. falciparum and 23 P. vivax field isolates were collected for ex vivo drug susceptibility testing. Reliable paired data between LM and FC was obtained for 88 % (295/334) of these assays. The median difference of derived IC50 values varied from -5.4 to 6.1 nM, associated with 0.83-1.23 fold change in IC50 values between LM and FC. In 15 assays (5.1 %), the derived difference of IC50 estimates was beyond the 95 % limits of agreement; in eleven assays (3.7 %), this was attributable to low parasite growth (final schizont count < 40 %), and in four assays (1.4 %) due to low initial parasitaemia at the start of assay (<2000 µl(-1)). In a subset of seven samples, LM, single and double staining FC techniques generated similar IC50 values.

CONCLUSIONS

A single staining FC-based assay using a portable cytometer provides a simple, fast and versatile platform for field surveillance of ex vivo drug susceptibility in clinical P. falciparum and P. vivax isolates.

Для цитирования: Wirjanata Grennady, Handayuni Irene, Prayoga Pak, Apriyanti Dwi, Chalfein Ferryanto, Sebayang Boni F, Kho Steven, Noviyanti Rintis, Kenangalem Enny, Campo Brice, Poespoprodjo Jeanne Rini, Price Ric N, Marfurt Jutta. Quantification of Plasmodium ex vivo drug susceptibility by flow cytometry.. Malaria journal. 2015. DOI: 10.1186/s12936-015-0940-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.