MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.cccn.2004.04.009

Медицинская библиотека · Clinica chimica acta; international journal of clinical chemistry · 2004

Glycogen storage disease type II: enzymatic screening in dried blood spots on filter paper.

Chamoles Néstor A, Niizawa Gabriela, Blanco Mariana, Gaggioli Daniela, Casentini Carina

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Glycogen storage disease II is characterized by a deficiency of the lysosomal enzyme acid alpha-glucosidase. Currently, glycogen storage disease II is diagnosed by demonstrating the virtual absence or a marked reduction of acid alpha-glucosidase activity in muscle biopsies, cultured fibroblasts, or purified lymphocytes. Early diagnosis and treatment of glycogen storage disease II are considered to be critical for maximum efficacy of the enzyme replacement therapies that are in development. However, these existing diagnostic methods are not suited for newborn screening. We developed an assay useful for newborn screening for glycogen storage disease II.

METHODS

A series of three enzyme assays to measure the alpha-glucosidase activities in dried blood spots on filter paper was developed. The measurement of acid alpha-glucosidase activity with minimal interference by other alpha-glucosidases was accomplished using maltose as an inhibitor. The method was used on samples from glycogen storage disease II patients, obligate heterozygotes, and healthy controls.

RESULTS

Glycogen storage disease II patients were distinguished from carriers and healthy controls using the series of enzyme assays.

CONCLUSIONS

We developed a simple and noninvasive screening method for glycogen storage disease II. The method could be incorporated into newborn screening.

Для цитирования: Chamoles Néstor A, Niizawa Gabriela, Blanco Mariana, Gaggioli Daniela, Casentini Carina. Glycogen storage disease type II: enzymatic screening in dried blood spots on filter paper.. Clinica chimica acta; international journal of clinical chemistry. 2004. DOI: 10.1016/j.cccn.2004.04.009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.