MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/mus.10330

Медицинская библиотека · Muscle & nerve · 2003

Diagnostic utility of a modified forearm ischemic exercise test and technical issues relevant to exercise testing.

Tarnopolsky Mark, Stevens Leslie, MacDonald Jay R, Rodriguez Christine, Mahoney Douglas, Rush Jim, Maguire John

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

The sensitivity and specificity of a modified forearm ischemic test (FIT) are described in the diagnosis of glycogen storage disease, myoadenylate deaminase deficiency, and mitochondrial disease. FIT and muscle biopsy results were reviewed from 99 patients (glycogen storage disease [GSD], myoadenylate deaminase deficiency [AMPD], mitochondrial disease [MITO], miscellaneous neuromuscular disorders, and controls). The influence of catheter placement and an antecedent sugar bolus were also assessed in healthy young men. The FIT had a sensitivity of 1.00 and a specificity of 1.00 for a diagnosis of GSD, whereas the corresponding values were 1.00 and 0.37 for AMPD deficiency. A baseline lactate of >2.5 mmol/L provided the highest sensitivity (0.62) and specificity (1.00) for MITO disease. A baseline and +1 min sample provided optimal sensitivity and specificity for GSD and AMPD deficiency. Catheter placement in any vein other than the ipsilateral antecubital resulted in attenuated lactate responses (P < 0.0001). A pre-FIT sugar bolus did not alter the postexercise lactate or ammonia response. Thus, a modified FIT was helpful in the diagnosis of GSD and excluding AMPD deficiency, but not in the diagnosis of MITO disease. Catheter placement is critical to the interpretation of a FIT, whereas pretesting diet is less important.

Для цитирования: Tarnopolsky Mark, Stevens Leslie, MacDonald Jay R, Rodriguez Christine, Mahoney Douglas, Rush Jim, Maguire John. Diagnostic utility of a modified forearm ischemic exercise test and technical issues relevant to exercise testing.. Muscle & nerve. 2003. DOI: 10.1002/mus.10330.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.