MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1024/0301-1526/a000905

Медицинская библиотека · VASA. Zeitschrift fur Gefasskrankheiten · 2020

Lack of durability after transarterial ethylene-vinyl alcohol copolymer-embolization of type II endoleak following endovascular abdominal aortic aneurysm repair.

Menges Anna-Leonie, Trenner Matthias, Radu Oksana, Beddoe Daisy, Kallmayer Michael, Zimmermann Alexander, Eckstein Hans-Henning

СтатьяПеревод пока не подготовлен

Аннотация

Background

Type II endoleak (T2EL) after endovascular aortic repair is associated with AAA sac enlargements in up to 25%, reduction of attachment zones and rarely with aortic rupture. Indications for therapy and efficacy of interventions of T2EL are not clearly established. Transarterial embolization with application of ethylene-vinyl alcohol copolymer has been described with varying outcomes. Aim of this study is to evaluate durability of OnyxTM embolization (OE) in T2EL in a consecutive series at a single tertiary vascular center. Patients and methods: Demographic data, technical success, pre- and postoperative aneurysm growth, morbidity, mortality and reintervention rates during hospital stay as well as in follow up were recorded in patients treated with OE for T2EL between 01/2015 and 12/2017. The primary endpoint was defined as persistence or reoccurrence of T2EL (durability of OE).

Results

In total 15 patients (78 ± 6 years, 13 men) were treated with OE because of sac enlargement (average growth of 12 ± 8%, n = 12), persistent bleeding after AAA rupture (n = 2) or persistent T2EL with stable but large aneurysm diameter (n = 1). Mean length of stay was 8 ± 11 days. Technical success was 93.3% (n = 14). Inhospital-morbidity was 26.7%, in-hospital- and 1-year-mortality rate were 6.6% (n = 1) and 20.0% (n = 3). T2EL persisted in 20.0% (n = 3) despite of OE. Re-EL-II occurred after 40 (30-114) days in 33.3% (n = 5). Reintervention rate was 13.3% (n = 2, at day 48 and 319). Altogether clinical success with stable aneurysm diameter was achieved in 80.0% (n = 12), but durable elimination of EL was only achieved in 46.7% of patients (n = 7).

Conclusions

OE is technically possible in more than 90% of patients but might be associated with severe complications. Durability of this treatment is low, since T2EL persist or reoccur in more than 50% of all patients. OE of T2EL should be reserved for few selected cases.

Для цитирования: Menges Anna-Leonie, Trenner Matthias, Radu Oksana, Beddoe Daisy, Kallmayer Michael, Zimmermann Alexander, Eckstein Hans-Henning. Lack of durability after transarterial ethylene-vinyl alcohol copolymer-embolization of type II endoleak following endovascular abdominal aortic aneurysm repair.. VASA. Zeitschrift fur Gefasskrankheiten. 2020. DOI: 10.1024/0301-1526/a000905.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.