MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.neuroimage.2023.120379

Медицинская библиотека · NeuroImage · 2023

Outcome measures for electric field modeling in tES and TMS: A systematic review and large-scale modeling study.

Van Hoornweder Sybren, Nuyts Marten, Frieske Joana, Verstraelen Stefanie, Meesen Raf L J, Caulfield Kevin A

Систематический обзорСтатьяПоддержка исследования: вне правительства СШАПоддержка NIH: внешняя программаПеревод пока не подготовлен

Аннотация

BACKGROUND

Electric field (E-field) modeling is a potent tool to estimate the amount of transcranial magnetic and electrical stimulation (TMS and tES, respectively) that reaches the cortex and to address the variable behavioral effects observed in the field. However, outcome measures used to quantify E-fields vary considerably and a thorough comparison is missing.

OBJECTIVES

This two-part study aimed to examine the different outcome measures used to report on tES and TMS induced E-fields, including volume- and surface-level gray matter, region of interest (ROI), whole brain, geometrical, structural, and percentile-based approaches. The study aimed to guide future research in informed selection of appropriate outcome measures.

METHODS

Three electronic databases were searched for tES and/or TMS studies quantifying E-fields. The identified outcome measures were compared across volume- and surface-level E-field data in ten tES and TMS modalities targeting two common targets in 100 healthy individuals.

RESULTS

In the systematic review, we extracted 308 outcome measures from 202 studies that adopted either a gray matter volume-level (n = 197) or surface-level (n = 111) approach. Volume-level results focused on E-field magnitude, while surface-level data encompassed E-field magnitude (n = 64) and normal/tangential E-field components (n = 47). E-fields were extracted in ROIs, such as brain structures and shapes (spheres, hexahedra and cylinders), or the whole brain. Percentiles or mean values were mostly used to quantify E-fields. Our modeling study, which involved 1,000 E-field models and > 1,000,000 extracted E-field values, revealed that different outcome measures yielded distinct E-field values, analyzed different brain regions, and did not always exhibit strong correlations in the same within-subject E-field model.

CONCLUSIONS

Outcome measure selection significantly impacts the locations and intensities of extracted E-field data in both tES and TMS E-field models. The suitability of different outcome measures depends on the target region, TMS/tES modality, individual anatomy, the analyzed E-field component and the research question. To enhance the quality, rigor, and reproducibility in the E-field modeling domain, we suggest standard reporting practices across studies and provide four recommendations.

Для цитирования: Van Hoornweder Sybren, Nuyts Marten, Frieske Joana, Verstraelen Stefanie, Meesen Raf L J, Caulfield Kevin A. Outcome measures for electric field modeling in tES and TMS: A systematic review and large-scale modeling study.. NeuroImage. 2023. DOI: 10.1016/j.neuroimage.2023.120379.