Technical validation of real-world monitoring of gait: a multicentric observational study.
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Mazzà Claudia, Alcock Lisa, Aminian Kamiar, Becker Clemens, Bertuletti Stefano, Bonci Tecla, Brown Philip, Brozgol Marina, Buckley Ellen, Carsin Anne-Elie, Caruso Marco, Caulfield Brian, Cereatti Andrea, Chiari Lorenzo, Chynkiamis Nikolaos, Ciravegna Fabio, Del Din Silvia, Eskofier Björn, Evers Jordi, Garcia Aymerich Judith, Gazit Eran, Hansen Clint, Hausdorff Jeffrey M, Helbostad Jorunn L, Hiden Hugo, Hume Emily, Paraschiv-Ionescu Anisoara, Ireson Neil, Keogh Alison, Kirk Cameron, Kluge Felix, Koch Sarah, Küderle Arne, Lanfranchi Vitaveska, Maetzler Walter, Micó-Amigo M Encarna, Mueller Arne, Neatrour Isabel, Niessen Martijn, Palmerini Luca, Pluimgraaff Lucas, Reggi Luca, Salis Francesca, Schwickert Lars, Scott Kirsty, Sharrack Basil, Sillen Henrik, Singleton David, Soltani Abolfazi, Taraldsen Kristin, Ullrich Martin, Van Gelder Linda, Vereijken Beatrix, Vogiatzis Ioannis, Warmerdam Elke, Yarnall Alison, Rochester Lynn
Аннотация
METHODS AND ANALYSIS: This protocol was designed to establish the technical validity and patient acceptability of the approach used to quantify digital mobility in the real world by Mobilise-D, a consortium funded by the European Union (EU) as part of the Innovative Medicine Initiative, aiming at fostering regulatory approval and clinical adoption of DMOs.After defining the procedures for the metrological verification of an IMU-based device, the experimental procedures for the validation of algorithms used to calculate the DMOs are presented. These include laboratory and real-world assessment in 120 participants from five groups: healthy older adults; chronic obstructive pulmonary disease, Parkinson's disease, multiple sclerosis, proximal femoral fracture and congestive heart failure. DMOs extracted from the monitoring device will be compared with those from different reference systems, chosen according to the contexts of observation. Questionnaires and interviews will evaluate the users' perspective on the deployed technology and relevance of the mobility assessment.
ETHICS AND DISSEMINATION: The study has been granted ethics approval by the centre's committees (London-Bloomsbury Research Ethics committee; Helsinki Committee, Tel Aviv Sourasky Medical Centre; Medical Faculties of The University of Tübingen and of the University of Kiel). Data and algorithms will be made publicly available.
TRIAL REGISTRATION NUMBER: ISRCTN (12246987).