MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1530/eje-14-0112

Медицинская библиотека · European journal of endocrinology · 2014

External validation of the fatty liver index and lipid accumulation product indices, using 1H-magnetic resonance spectroscopy, to identify hepatic steatosis in healthy controls and obese, insulin-resistant individuals.

Cuthbertson Daniel J, Weickert Martin O, Lythgoe Daniel, Sprung Victoria S, Dobson Rebecca, Shoajee-Moradie Fariba, Umpleby Margot, Pfeiffer Andreas F H, Thomas E Louise, Bell Jimmy D, Jones Helen, Kemp Graham J

СтатьяПоддержка исследования: вне правительства СШАВалидационное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND AND AIMS: Simple clinical algorithms including the fatty liver index (FLI) and lipid accumulation product (LAP) have been developed as surrogate markers for non-alcoholic fatty liver disease (NAFLD), constructed using (semi-quantitative) ultrasonography. This study aimed to validate FLI and LAP as measures of hepatic steatosis, as determined quantitatively by proton magnetic resonance spectroscopy (1H-MRS).

METHODS

Data were collected from 168 patients with NAFLD and 168 controls who had undergone clinical, biochemical and anthropometric assessment. Values of FLI and LAP were determined and assessed both as predictors of the presence of hepatic steatosis (liver fat>5.5%) and of actual liver fat content, as measured by 1H-MRS. The discriminative ability of FLI and LAP was estimated using the area under the receiver operator characteristic curve (AUROC). As FLI can also be interpreted as a predictive probability of hepatic steatosis, we assessed how well calibrated it was in our cohort. Linear regression with prediction intervals was used to assess the ability of FLI and LAP to predict liver fat content. Further validation was provided in 54 patients with type 2 diabetes mellitus.

RESULTS

FLI, LAP and alanine transferase discriminated between patients with and without steatosis with an AUROC of 0.79 (IQR=0.74, 0.84), 0.78 (IQR=0.72, 0.83) and 0.83 (IQR=0.79, 0.88) respectively although could not quantitatively predict liver fat. Additionally, the algorithms accurately matched the observed percentages of patients with hepatic steatosis in our cohort.

CONCLUSIONS

FLI and LAP may be used to identify patients with hepatic steatosis clinically or for research purposes but could not predict liver fat content.

Для цитирования: Cuthbertson Daniel J, Weickert Martin O, Lythgoe Daniel, Sprung Victoria S, Dobson Rebecca, Shoajee-Moradie Fariba, Umpleby Margot, Pfeiffer Andreas F H, Thomas E Louise, Bell Jimmy D, Jones Helen, Kemp Graham J. External validation of the fatty liver index and lipid accumulation product indices, using 1H-magnetic resonance spectroscopy, to identify hepatic steatosis in healthy controls and obese, insulin-resistant individuals.. European journal of endocrinology. 2014. DOI: 10.1530/eje-14-0112.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.