DOI 10.1245/s10434-014-3940-y

Медицинская библиотека · Annals of surgical oncology · 2014

The use of modified four-dimensional computed tomography in patients with primary hyperparathyroidism: an argument for the abandonment of routine sestamibi single-positron emission computed tomography (SPECT).

Kukar Moshim, Platz Timothy A, Schaffner Timothy J, Elmarzouky Rania, Groman Adrienne, Kumar Shicha, Abdelhalim Ahmed, Cance William G

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Four-dimensional computed tomography (4D CT) has emerged as an extremely sensitive preoperative imaging modality for primary hyperparathyroidism compared with the historical use of sestamibi and ultrasound (US). Specialized volume rendering and technical modifications further enhance this technique for operative guidance while reducing radiation exposure.

METHODS

Patients undergoing parathyroidectomy for primary hyperparathyroidism from December 2010 to September 2013, carried out by two surgeons at a tertiary cancer center, were evaluated. Comparison was made between the three imaging modalities (4D CT, sestamibi, and US) for preoperative localization rate and accuracy. Biochemical parameters and radiation exposure were also analyzed.

RESULTS

A total of 202 patients were identified from the database and 200 patients were included in the analysis. All patients underwent 4D CT (100 %), 185 sestamibi (92.5 %) and 186 US (93 %). In patients with single-gland disease (n = 153), 4D CT, sestamibi, and US were positive in 96 %, 65.4 % and 57.7 % of patients, respectively and, when positive, were accurately localized in 97.2 %, 93.4 % and 96.3 % of patients, respectively. In patients with multigland disease (MGD) [n = 47], 4D CT, sestamibi, and US predicted MGD in 32 %, 0 %, and 13.6 % of patients, respectively. With our technique modification, radiation exposure from 4D CT approached that of sestamibi.

CONCLUSIONS

Low-dose, modified 4D CT with volume rendering when compared with sestamibi has a statistically significant higher positivity rate, improved accuracy rate, provides excellent images, superior surgical planning, and has a comparable radiation exposure risk profile. Consideration should be made for the abandonment of routine sestamibi single-positron emission computed tomography (SPECT), with 4D CT as the preoperative imaging modality of choice.

Для цитирования: Kukar Moshim, Platz Timothy A, Schaffner Timothy J, Elmarzouky Rania, Groman Adrienne, Kumar Shicha, Abdelhalim Ahmed, Cance William G. The use of modified four-dimensional computed tomography in patients with primary hyperparathyroidism: an argument for the abandonment of routine sestamibi single-positron emission computed tomography (SPECT).. Annals of surgical oncology. 2014. DOI: 10.1245/s10434-014-3940-y.