MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/aor.13897

Медицинская библиотека · Artificial organs · 2021

Outcomes of left ventricular assist device implantation for advanced heart failure in critically ill patients (INTERMACS 1 and 2): A retrospective study.

Zhigalov Konstantin, Van den Eynde Jef, Chrosch Thomas, Goerdt Lukas, Sá Michel Pompeu Barros Oliveira, Zubarevich Alina, Papathanasiou Maria, Wendt Daniel, Luedike Peter, Pizanis Nikolaus, Koch Achim, Schmack Bastian, Rassaf Tienush, Kamler Markus, Ruhparwar Arjang, Weymann Alexander

СтатьяПеревод пока не подготовлен

Аннотация

The use of left ventricular assist devices (LVADs) for advanced heart failure is becoming increasingly common. However, optimal timing and patient selection remain controversial. The aim of this study was to investigate outcomes of LVAD implantation for advanced heart failure in critically ill patients (INTERMACS 1 and 2). Between August 2010 and January 2020, 207 consecutive patients underwent LVAD implantation. Overall survival, major adverse events, and laboratory parameters were compared between patients in INTERMACS 1-2 (n = 107) and INTERMACS 3-5 (n = 100). Preoperative white blood cells, C-reactive protein, procalcitonin, bilirubin, alanine transaminase, and lactate dehydrogenase were all significantly higher in INTERMACS 1-2 when compared to INTERMACS 3-5 (P < .05). During hospitalization following LVAD implantation, patients in INTERMACS 1-2 were more likely to develop major infections (41.1% vs. 23.0%, P = .005), respiratory failure (57.9% vs. 25.0%, P < .001), mild (20.6% vs. 8.0%, P = .010), and moderate (31.8% vs. 7.0%, P < .001) right heart failure, and acute renal dysfunction (56.1% vs. 6.0%, P < .001). During a median follow-up of 2.00 years (interquartile range (IQR) 0.24-3.39 years), they had a higher incidence of thoracic (15.9% vs. 4.0%, P = .005) and gastrointestinal bleeding (21.5% vs. 11.0%, P = .042), as well as right heart failure (18.7% vs. 1%, P < .001). Risk of death was significantly higher in the INTERMACS 1-2 group (hazards ratio (HR) 1.64, 95% CI 1.12-2.40, P = .011). LVAD implantation in critically ill patients is associated with increased morbidity and mortality. Our results suggest that decision for LVAD should be not be delayed until INTERMACS 1 and 2 levels whenever possible.

Для цитирования: Zhigalov Konstantin, Van den Eynde Jef, Chrosch Thomas, Goerdt Lukas, Sá Michel Pompeu Barros Oliveira, Zubarevich Alina, Papathanasiou Maria, Wendt Daniel, Luedike Peter, Pizanis Nikolaus, Koch Achim, Schmack Bastian, Rassaf Tienush, Kamler Markus, Ruhparwar Arjang, Weymann Alexander. Outcomes of left ventricular assist device implantation for advanced heart failure in critically ill patients (INTERMACS 1 and 2): A retrospective study.. Artificial organs. 2021. DOI: 10.1111/aor.13897.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.