MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/rli.0000000000000175

Медицинская библиотека · Investigative radiology · 2015

Magnetic resonance imaging of pathogenic protozoan parasite Entamoeba histolytica labeled with superparamagnetic iron oxide nanoparticles.

Ernst Thomas M, Fehling Helena, Bernin Hannah, Zaruba Mareen D, Bruchhaus Iris, Adam Gerhard, Ittrich Harald, Lotter Hannelore

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVES

The aim of this study was to establish a noninvasive tracking of the pathogenic parasite Entamoeba histolytica (Eh) after superparamagnetic iron oxide (SPIO) labeling by magnetic resonance imaging (MRI) on a single-cell level in vitro and in vivo in a mouse model for amebic liver abscess (ALA).

MATERIALS AND

METHODS

Local institutional review committee on animal care approved all animal experiments. Entamoeba histolytica trophozoites were labeled with SPIO nanoparticles (SPIO-Eh). The uptake of SPIO by Eh was optimized using flow cytometry and visualized by bright field, fluorescence, and transmission electron microscopy. The viability of SPIO-Eh was assessed in vitro by determination of growth and ingestion rate of red blood cells. Migration of SPIO-Eh was proven by in vitro MRI in a preclinical 7 T MRI system using continually repeated MRI scans. In vivo distribution of SPIO-Eh within the mouse liver was assessed qualitatively and quantitatively by serial respiration-triggered T2*-weighted MRI, T2-weighted MRI, and R2* MR relaxometry up to 5 days after injection and correlated with immunohistology of the liver sections after removal.

RESULTS

Entamoeba histolytica can be efficiently labeled with SPIO without influence on parasite growth rate or phagocytic capacity. In vitro dynamic MRI allowed real-time migration monitoring and determination of velocity of single SPIO-Eh. In vivo SPIO-Eh showed signal decrease in T2*-weighted and increase of R2* in ALA formations. Motility of SPIO-Eh was necessary to induce ALA formations.

CONCLUSIONS

The present study demonstrates the feasibility of an efficient magnetic labeling and a noninvasive in vitro and in vivo MR tracking of the pathogenic protozoan Eh in a mouse model for ALA, thus representing in future a noninvasive imaging tool to study parasite, as well as on host-specific pathomechanisms.

Для цитирования: Ernst Thomas M, Fehling Helena, Bernin Hannah, Zaruba Mareen D, Bruchhaus Iris, Adam Gerhard, Ittrich Harald, Lotter Hannelore. Magnetic resonance imaging of pathogenic protozoan parasite Entamoeba histolytica labeled with superparamagnetic iron oxide nanoparticles.. Investigative radiology. 2015. DOI: 10.1097/rli.0000000000000175.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.