Skin to Intramuscular Compartment Thigh Measurement by Ultrasound in Pediatric Population.

Duong Myto, Botchway Albert, Dela Cruz Jonathan, Austin Richard, McDaniel Kevin, Jaeger Cassie

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

Pediatric obesity threatens the efficacy of medications given intramuscularly. In anaphylactic patients, epinephrine auto-injector needle lengths are potentially too short to reach the muscle compartment in patients with elevated body habitus. The objective of the study was to determine needle-length requirements for intramuscular injections in pediatric patients.

METHODS

We used ultrasound to measure the distance from skin to muscle compartment of the thigh in 200 pediatric patients of various weight and body mass index who presented to the emergency department.

RESULTS

Patients with higher body mass index had an increased distance to muscle and bone. If current recommendations were followed, 5% of patients within the EpiPen adult weight category and 11% of patients within the Centers for Disease Control and Prevention weight category would have potentially used a needle inadequate in length for intramuscular injections.

CONCLUSION

With the increase in childhood obesity, needle lengths may be too short to effectively deliver medications to the intramuscular compartment. Needle length should be evaluated to accommodate pediatric patients with increased skin to muscle distance.

Для цитирования: Duong Myto, Botchway Albert, Dela Cruz Jonathan, Austin Richard, McDaniel Kevin, Jaeger Cassie. Skin to Intramuscular Compartment Thigh Measurement by Ultrasound in Pediatric Population.. The western journal of emergency medicine. 2017. DOI: 10.5811/westjem.2016.12.32279.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.