MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/ijerph191912606

Медицинская библиотека · International journal of environmental research and public health · 2022

High-Level Mobility of Trans-Tibial Prosthesis Users Wearing Commercial and sPace Energy-Storing Prosthetic Feet.

Rakbangboon Thanyaporn, Guerra Gary, Kla-Arsa Saloottra, Padungjaroen Uthumporn, Tangpornprasert Pairat, Virulsri Chanyaphan, Sasaki Kazuhiko

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

UNLABELLED: Outcomes of users provided with a commercial ESR Vari-Flex foot (Össur, Reykjavik, Iceland) and a locally designed sPace foot were investigated. Step activity with users' own prosthetic foot compared to the sPace foot was explored.

METHODS

Eleven individuals with unilateral trans-tibial amputation participated and were provided with an sPace and Vari-Flex foot. Ten- and twenty-meter walk tests (10/20MWT) at comfortable and fast walking speeds (CWS/FWS), the two-minute walk test (2-MWT) and Comprehensive High-Level Activity Mobility Predictor (CHAMP) were administered. A subgroup was provided a pedometer to record their steps over a 7-day period in their own foot and later the sPace.

RESULTS

The sPace foot performed well in a battery of high-level mobility outcome measures. On CHAMP, participants scored 16.94 ± 5.41 and 16.72 ± 6.09 with the sPace and Vari-Flex feet, respectively. Subgroup testing of step activity showed 4490 ± 3444 steps in users' own feet and 3115 ± 1967 in the sPace foot, p = 0.176.

CONCLUSIONS

Participants using the sPace foot were capable of performing walking, high-level mobility and activity outcome measures.

Для цитирования: Rakbangboon Thanyaporn, Guerra Gary, Kla-Arsa Saloottra, Padungjaroen Uthumporn, Tangpornprasert Pairat, Virulsri Chanyaphan, Sasaki Kazuhiko. High-Level Mobility of Trans-Tibial Prosthesis Users Wearing Commercial and sPace Energy-Storing Prosthetic Feet.. International journal of environmental research and public health. 2022. DOI: 10.3390/ijerph191912606.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.