Magnetic resonance in medicine · 2025

Modeling the effect of in-plane magnetic field gradients on asymmetric spin-echo images with echo-planar imaging readout.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Wallimann Philipp, Tang Patrick L Y, Arzanforoosh Fatemeh, Tanadini-Lang Stephanie, Andratschke Nicolaus, Smits Marion, Warnert Esther A H

Аннотация

PURPOSE: To describe the impact of macroscopic magnetic field gradients (MFGs) in the phase-encoding direction on MR images acquired with an asymmetric spin echo (ASE) sequence with echo-planar imaging (EPI) readout.

METHODS: In EPI, the center of k-space is read out at a shifted time point in the presence of phase-encoding direction MFGs. The ASE signal equation was extended to account for a locally varying temporal offset τ eff $$ {\tau}_{eff} $$ between the spin echo and echo time due to MFGs. The impact on estimated quantitative blood oxygen level dependent (qBOLD) parameters was assessed using simulations. A B 0 $$ {B}_0 $$ map and ASE images with four different phase-encoding directions and two different parallel-imaging factors were acquired from 2 healthy volunteers. A robust linear regression was performed between the signal dependence on the phase-encoding direction and MFGs calculated based on the B 0 $$ {B}_0 $$ map to test the derived signal equation.

RESULTS: Simulated qBOLD parameters were substantially modified by the local τ eff $$ {\tau}_{eff} $$ . The volunteer images showed a logarithmic signal intensity ratio between images acquired with reversed phase-encoding directions that showed a linear dependence on both the calculated MFGs in the phase-encoding direction and the nominal temporal offset τ $$ \tau $$ . The effect was strongly reduced for the images with the higher parallel-imaging factor.

CONCLUSION: The effects of phase-encoding-direction MFGs on volunteer ASE images is consistent with the proposed signal model and relevant for qBOLD measurements. This highlights the necessity to correct or mitigate in-plane MFGs in ASE EPI, such as using a high parallel-imaging factor.