MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jemermed.2007.11.064

Медицинская библиотека · The Journal of emergency medicine · 2008

Ultrasound can accurately guide gastrostomy tube replacement and confirm proper tube placement at the bedside.

Wu Teresa S, Leech Stephen J, Rosenberg Marcy, Huggins Charles, Papa Linda

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Malfunctioning or dislodged gastrostomy tubes (G-tubes) often require urgent replacement and reinsertion in the Emergency Department (ED). Few data exist regarding the best technique for bedside catheter replacement and verification, and individual operator preferences vary. Although a few reports have described the use of ultrasound guidance during the initial percutaneous insertion, no data are available concerning its role during subsequent G-tube replacements.

OBJECTIVE

We sought to investigate the utility of bedside ultrasonography during G-tube replacements in the ED.

METHODS

This was a prospective pilot study conducted at a Level 1 Trauma Center with an annual census of 90,000 patients. Seven adults and three children with malfunctioning G-tubes were enrolled. Three tubes were cracked and leaking, and seven tubes had been dislodged. Under ultrasound, a new G-tube was inserted through the previously fashioned tract. After insertion, color Doppler was applied over the catheter tip to enhance visualization during gentle tube oscillation.

RESULTS

Ultrasound successfully visualized G-tube replacement in all 10 patients. Application of color Doppler over the G-tube tip during catheter oscillation enhanced placement confirmation. Sonographic findings were corroborated with gastric content aspiration, contrast-enhanced radiographs, and successful use of the new G-tubes. No false tracts were identified during ultrasound-guided insertion, post-procedure sonographic confirmation, or subsequent radiographs.

CONCLUSION

The improper replacement of a G-tube can lead to devastating consequences. Verifying appropriate placement through aspirate evaluation can be misleading, and post-procedure radiographs increase radiation exposure and ED wait times. Bedside ultrasonography can be used to guide catheter insertion while providing a safe and quick adjunct to confirm proper G-tube placement.

Для цитирования: Wu Teresa S, Leech Stephen J, Rosenberg Marcy, Huggins Charles, Papa Linda. Ultrasound can accurately guide gastrostomy tube replacement and confirm proper tube placement at the bedside.. The Journal of emergency medicine. 2008. DOI: 10.1016/j.jemermed.2007.11.064.