MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.eururo.2013.10.040

Медицинская библиотека · European urology · 2013

180-W XPS GreenLight laser vaporisation versus transurethral resection of the prostate for the treatment of benign prostatic obstruction: 6-month safety and efficacy results of a European Multicentre Randomised Trial--the GOLIATH study.

Bachmann Alexander, Tubaro Andrea, Barber Neil, d'Ancona Frank, Muir Gordon, Witzsch Ulrich, Grimm Marc-Oliver, Benejam Joan, Stolzenburg Jens-Uwe, Riddick Antony, Pahernik Sascha, Roelink Herman, Ameye Filip, Saussine Christian, Bruyère Franck, Loidl Wolfgang, Larner Tim, Gogoi Nirjan-Kumar, Hindley Richard, Muschter Rolf, Thorpe Andrew, Shrotri Nitin, Graham Stuart, Hamann Moritz, Miller Kurt, Schostak Martin, Capitán Carlos, Knispel Helmut, Thomas J Andrew

Сравнительное исследованиеСтатьяМногоцентровое исследованиеРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

The comparative outcome with GreenLight (GL) photoselective vaporisation of the prostate and transurethral resection of the prostate (TURP) in men with lower urinary tract symptoms due to benign prostatic obstruction (BPO) has been questioned.

OBJECTIVE

The primary objective of the GOLIATH study was to evaluate the noninferiority of 180-W GL XPS (XPS) to TURP for International Prostate Symptom Score (IPSS) and maximum flow rate (Qmax) at 6 mo and the proportion of patients who were complication free.

DESIGN, SETTING, AND

PARTICIPANTS

Prospective randomised controlled trial at 29 centres in 9 European countries involving 281 patients with BPO.

INTERVENTION: 180-W GL XPS system or TURP.

OUTCOME MEASUREMENTS AND STATISTICAL ANALYSIS: Measurements used were IPSS, Qmax, prostate volume (PV), postvoid residual (PVR) and complications, perioperative parameters, and reintervention rates. Noninferiority was evaluated using one-sided tests at the 2.5% level of significance. The statistical significance of other comparisons was assessed at the (two-sided) 5% level.

RESULTS AND LIMITATIONS: The study demonstrated the noninferiority of XPS to TURP for IPSS, Qmax, and complication-free proportion. PV and PVR were comparable between groups. Time until stable health status, length of catheterisation, and length of hospital stay were superior with XPS (p<0.001). Early reintervention rate within 30 d was three times higher after TURP (p=0.025); however, the overall postoperative reintervention rates were not significantly different between treatment arms. A limitation was the short follow-up.

CONCLUSIONS

XPS was shown to be noninferior (comparable) to TURP in terms of IPSS, Qmax, and proportion of patients free of complications. XPS results in a lower rate of early reinterventions but has a similar rate after 6 mo.

TRIAL REGISTRATION: ClinicalTrials.gov, identifier NCT01218672.

Для цитирования: Bachmann Alexander, Tubaro Andrea, Barber Neil, d'Ancona Frank, Muir Gordon, Witzsch Ulrich, Grimm Marc-Oliver, Benejam Joan, Stolzenburg Jens-Uwe, Riddick Antony, Pahernik Sascha, Roelink Herman, Ameye Filip, Saussine Christian, Bruyère Franck, Loidl Wolfgang, Larner Tim, Gogoi Nirjan-Kumar, Hindley Richard, Muschter Rolf, Thorpe Andrew, Shrotri Nitin, Graham Stuart, Hamann Moritz, Miller Kurt, Schostak Martin, Capitán Carlos, Knispel Helmut, Thomas J Andrew. 180-W XPS GreenLight laser vaporisation versus transurethral resection of the prostate for the treatment of benign prostatic obstruction: 6-month safety and efficacy results of a European Multicentre Randomised Trial--the GOLIATH study.. European urology. 2013. DOI: 10.1016/j.eururo.2013.10.040.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.