Time-efficient simultaneous fat and water cardiac cine imaging using spiral magnetic resonance imaging.

СтатьяСравнительное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Chao Tzu Cheng, Wang Dinghui, Pipe James G, Leiner Tim

Аннотация

BACKGROUND: Cardiac cine imaging is routinely used in patient with suspected or known cardiac dysfunction. Water and fat (W/F) separated cardiovascular magnetic resonance (CMR) will be helpful to distinguish adipose tissue, blood, and myocardium. Inclusion of a multi-echo acquisition in the conventional balanced steady-state free precession (bSSFP) cine sequence can introduce artifacts and reduce temporal resolution. Spiral MRI is known for its signal-to-noise ratio (SNR) efficiency and has the potential to improve temporal efficiency for W/F separated cine imaging. The present work implements a spoiled gradient echo sequence (SPGR) with spiral trajectory to obtain W/F separated cine images simultaneously.

METHODS: Three different sequences were performed for comparison, a Cartesian 2-TE bSSFP sequence, a Cartesian 3-TE bSSFP sequence, and the proposed spiral SPGR sequence. Five volunteers were recruited for the scans on a 1.5T scanner with spatial resolution 1.7×1.7×8.0mm3 over a 400×400mm2 FOV. In addition to qualitative comparisons, a quantitative measurement is performed in terms of the contrast-to-noise ratio (CNR).

RESULTS: The proposed method to obtain W/F separated cine images provides better temporal efficiency and fewer artifacts compared to conventional Cartesian bSSFP sequences. The 2-TE bSSFP features the highest artifact level, including susceptibility artifacts and fat/water swaps. The proposed method reduces scan time by approximately 50% with similar spatial and temporal resolution with lower specific absorption rate (SAR). The contrast between the blood pool and myocardium is higher when using the spiral readout (p≤0.05). The results suggest that the presented sequence has potential to facilitate simultaneous imaging for water and fat components in a cine scan while shortening exam time and lowering SAR.

Предметные рубрики MeSH