MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00330-015-4065-9

Медицинская библиотека · European radiology · 2015

Non-contrast-enhanced MR angiography using time-spin labelling inversion pulse technique for detecting crossing renal vessels in children with symptomatic ureteropelvic junction obstruction: comparison with surgical findings.

Brucher Nicolas, Vial Julie, Baunin Christiane, Labarre David, Meyrignac Olivier, Juricic Michel, Bouali Ourdia, Abbo Olivier, Galinier Philippe, Sans Nicolas

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

Investigate the feasibility and evaluate the accuracy of non-contrast-enhanced MR angiography (NC-MRA) using time-spin labelling inversion pulse (time-SLIP)to identify crossing renal vessels (CRVs) in children requiring surgical treatment of ureteropelvic junction (UPJ) obstructionand compare to laparoscopic findings.

MATERIALS AND

METHODS

Nineteen children ranging from 6 to 16 years of age underwent NC-MRA using the time-SLIP technique before surgery. Two independent readers analysed the MRA images. Number of renal arteries and presence or absence of CRVs were identified and compared with surgicalfindings. Image quality was assessed, as well as the presence of CRVs and measurement of renal pelvis diameter. Intra and inter-reader agreement was calculated using Cohen's kappa coefficient and Bland-Altman plots.

RESULTS

The overall image quality was fair or good in 88% of cases. NC-MRA demonstrated CRVs at the level of the obstruction in 10 children and no CRV in 9 children. All were confirmed intra-operatively except in one of the nine children. Sensitivity, specificity, NPV, PPV for predicting CRVs were 92%, 100%, 100% and 87.5%, respectively, for both readers.

CONCLUSION

NC-MRA is a good alternative to contrast-enhanced MRA and CT scanning for identifying CRVs in children with symptomatic UPJ.

KEY POINTS: • Time-SLIP technique offers acceptable imaging quality for identifying crossing renal vessel. • Time-SLIP technique is easy to apply to the renal MRA examination. • Time-SLIP technique is an alternative to contrast-enhanced MRA and CT scanning.

Для цитирования: Brucher Nicolas, Vial Julie, Baunin Christiane, Labarre David, Meyrignac Olivier, Juricic Michel, Bouali Ourdia, Abbo Olivier, Galinier Philippe, Sans Nicolas. Non-contrast-enhanced MR angiography using time-spin labelling inversion pulse technique for detecting crossing renal vessels in children with symptomatic ureteropelvic junction obstruction: comparison with surgical findings.. European radiology. 2015. DOI: 10.1007/s00330-015-4065-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.